Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
520A102 81541 A 5 2 E TX
L505000035 36090 A 5 2 5 TX
C505024424 88818 A 5 2 5 TX
2039333PC5 10001 A 3 2 A TX

CAGE Information

Code Company
10001 NAVAIR AND NAVSEA MANAGED ORIGINAL D
81541 SENSATA TECHNOLOGIES MARYLAND INC
36090 LOCKHEED MARTIN LIBRASCOPE CORP
88818 KEARFOTT CORPORATION DBA KEARFOTT DI

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.500 MINIMUM AT 200 PCT SINGLE LOCATION AND 4.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING
AAQL BODY STYLE SINGLE POLE TYPE
ABXD BUSHING LENGTH 0.189 INCHES NOMINAL
THSD THREAD SERIES DESIGNATOR UNEF
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CQJX NOMINAL THREAD SIZE 0.375 INCHES
CPRJ TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 1.0 AMPERES AC SINGLE LOCATION
ADAQ BODY LENGTH 1.750 INCHES NOMINAL
AKPX POLE QUANTITY 1
CPRQ RESET METHOD MANUAL
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 500.0 AC SINGLE LOCATION
TTQY TERMINAL TYPE AND QUANTITY 2 WIRE HOOK
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.630 INCHES NOMINAL
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 135.0 SINGLE LOCATION
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.687 INCHES NOMINAL
ADTV CASE MATERIAL METAL
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
FREQ FREQUENCY IN HERTZ 400.0 SINGLE LOCATION
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
CMLP THREAD QUANTITY PER INCH 32
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
ADAT BODY WIDTH 0.625 INCHES MAXIMUM
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120.0 AC SINGLE LOCATION

Similar Parts