Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
DMS 81010B 16236 A 5 9 9 TX
612465 98897 A C 1 3 TX AG
MS24153-D1 96906 M 2 2 E TX
9565H70A 81640 A C 1 3 TX AF
AN3342-2 88044 M C 1 E TX AF
MIL-PRF-6106 81349 M 4 1 4 ZZ
MIL-R-6106 81349 M 5 9 E TX

CAGE Information

Code Company
16236 DLA LAND AND MARITIME
98897 LOCKHEED MARTIN CORPORATION DBA LOCK
96906 MILITARY STANDARDS PROMULGATED BY MI
81640 EATON CORPORATION DBA FLUID POWER DI
88044 AERONAUTICAL STANDARDS GROUP DEPT OF
81349 MILITARY SPECIFICATIONS PROMULGATED

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 50.0 AMPERES AC RESISTIVE LOAD AND 50.0 AMPERES DC RESISTIVE LOAD
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.875 INCHES NOMINAL SINGLE MOUNTING FACILITY
AKDX WINDING QUANTITY 2
ABHP OVERALL LENGTH 6.000 INCHES MAXIMUM
ADZC ENVIRONMENTAL PROTECTION DUSTPROOF
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 50.0 AMPERES AC INDUCTIVE LOAD AND 50.0 AMPERES DC INDUCTIVE LOAD
AFJN FRAGILITY FACTOR MODERATELY RUGGED
APCN COIL QUANTITY 2
TEST TEST DATA DOCUMENT 81349-MIL-R-6106 SPECIFICATION
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 5.125 INCHES NOMINAL SINGLE MOUNTING FACILITY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 50.0 AMPERES AC MOTOR LOAD AND 50.0 AMPERES DC MOTOR LOAD
CBME CUBIC MEASURE 88.490 CUBIC INCHES
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.218 INCHES NOMINAL SINGLE MOUNTING FACILITY
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
ADTV CASE MATERIAL PLASTIC
APNQ ARC QUENCHING METHOD AIR
CRXH TIME DELAY 0.01 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
AKSL PURPOSE FOR WHICH DESIGNED GENERAL
ABMK OVERALL WIDTH 4.453 INCHES MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 12 THREADED STUD ALL FUNCTIONS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION
APNP DUTY TYPE CONTINUOUS
ABKW OVERALL HEIGHT 3.312 INCHES MAXIMUM
ZZZK SPECIFICATION/STANDARD DATA 96906-MS24153 GOVERNMENT STANDARD
CQYJ MOUNTING FACILITY PATTERN RECTANGULAR SINGLE MOUNTING FACILITY

Similar Parts

DMS 81010B , DMS81010B , 5945-00-822-1345 , 5945008221345 , 008221345 , DMS 81010B , 612465 , MS24153-D1 , 9565H70A , AN3342-2 , MIL-PRF-6106 , MIL-R-6106 ,