NIIN Output Data
Definition:
AN ITEM CONSISTING OF AN ELECTRICALLY CONDUCTIVE MATERIAL DESIGNED TO FURNISH A SURFACE WHICH WILL PHYSICALLY AND ELECTRICALLY MEET ANOTHER CONDUCTING SURFACE FOR THE PURPOSE OF TRANSFERRING ELECTRICAL ENERGY AND/OR OPENING AND CLOSING CIRCUITS. INCLUDES MOVING CONTACTS WHICH MAKE AND/OR SLIDE OVER STATIONARY CONTACTS OR OTHER STATIONARY CONDUCTIVE MATERIAL TO A RESULTING FIXED POSITION. EXCLUDES ITEMS WHICH ARE USED IN CONJUNCTION WITH CONTINUALLY MOVING SURFACES OR WHICH MAKE CONTACT BY GRIPPING ACTION OF THE CONTACT SURFACES. SEE ALSO CLIP, ELECTRICAL; CLAMP, ELECTRICAL; BRUSH, ELECTRICAL CONTACT; PLUG, TIP; AND JACK, TIP.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
372-2234-010 | 95105 | A | 5 | 2 | 5 | TX | ||
NA1112-010 | 57863 | A | 5 | 2 | 5 | TX | ||
86012-1 | 00779 | A | 3 | 9 | 5 | TX | ||
372-2234-010 | 13499 | A | 7 | 2 | 1 | TX | ||
86010 | 00779 | A | 5 | 9 | 1 | TX |
CAGE Information
Code | Company |
---|---|
00779 | TYCO ELECTRONICS CORPORATION |
95105 | ROCKWELL COLLINS INC. DIV GOVERNMENT |
57863 | NORTH AMERICAN SPECIALTIES CORP |
13499 | ROCKWELL COLLINS INC. DBA GOVERNMENT |
Federal Supply Class
Title
MISCELLANEOUS ELECTRICAL AND ELE
Inclusions:
INCLUDES PERMANENT MAGNETS AND MAGNETOSTRICTION ELEMENTS; CAPS, CLIPS, AND CONTACTS, ELECTRICAL.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
PMLC | PRECIOUS MATERIAL AND LOCATION | EXTERNAL SURFACES GOLD |
PRMT | PRECIOUS MATERIAL | GOLD |
ABKW | OVERALL HEIGHT | 0.070 INCHES NOMINAL |
AKRN | SLOT ACCOMMODATION WIDTH | ANY ACCEPTABLE |
STYL | STYLE DESIGNATOR | SOCKET CONTACT |
SFTT | SURFACE TREATMENT | GOLD CONTACT AND NICKEL CONTACT |
MATT | MATERIAL | COPPER ALLOY BODY |
ABHP | OVERALL LENGTH | 0.785 INCHES NOMINAL |
PMWT | PRECIOUS MATERIAL AND WEIGHT | 0.005 GOLD GRAINS, TROY |
MATT | MATERIAL | COPPER ALLOY CONTACT |
SFTT | SURFACE TREATMENT | GOLD BODY AND NICKEL BODY |
AXGY | MOUNTING METHOD | ANY ACCEPTABLE |
AFQJ | CABLE ENTRANCE DIAMETER | ANY ACCEPTABLE |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG AXIALLY AT ONE END |
ABMK | OVERALL WIDTH | 0.060 INCHES NOMINAL |