NIIN Output Data
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
M3190/05-20-0 | 81349 | M | 2 | 2 | 3 | ZZ | ||
MIL-I-3190 | 81349 | M | 4 | 1 | 4 | CX |
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGT | WALL THICKNESS | ANY ACCEPTABLE |
ABJH | TEMP RATING | 200.0 DEG CELSIUS |
HUES | COLOR | BLACK |
ABHP | OVERALL LENGTH | 2.500 FEET MINIMUM AND 3.500 FEET MAXIMUM |
FLEX | FLEXIBILITY | FLEXIBLE |
AGBE | IMPREGNATION MATERIAL | SILICONE VARNISH |
ADYY | COATING MATERIAL | SILICONE VARNISH |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ZZZT | NONDEFINITIVE SPEC/STD DATA | H-A-1 CLASS AND 2AWG SIZE |
AARX | INSIDE DIAMETER | 0.258 INCHES MINIMUM AND 0.278 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | 2 AWG |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
MATL | MATERIAL | GLASS BRAID, MIL-I-3190, CLASS H-A-1 |
ADZC | ENVIRONMENTAL PROTECTION | ANY ACCEPTABLE |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 7000.0 |