NIIN Output Data

NIIN:
NSN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
64A8D132 10001 A 3 2 1 KE
64A8D132 30003 A 5 2 1 KE

CAGE Information

Code Company
10001 NAVAIR AND NAVSEA MANAGED ORIGINAL D
30003 NAVAL AIR SYSTEMS COMMAND

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 350.00 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
ABMK OVERALL WIDTH 1.410 INCHES NOMINAL
AAJD THREAD CLASS (NON-CORE) 2B SINGLE GROUP
AKNA INCLOSURE TYPE FULLY INCLOSED
CQLC WINDING TAP LOCATION (NON-CORE) NEUTRAL TAP SINGLE COMPONENT ALL SECONDARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
CQLC WINDING TAP LOCATION (NON-CORE) NEUTRAL TAP SINGLE COMPONENT SINGLE PRIMARY
TTQY TERMINAL TYPE AND QUANTITY 16 TAB, SOLDER LUG
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 16.60 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
ABKW OVERALL HEIGHT 2.630 INCHES NOMINAL
CRBZ WINDING OPERATING CURRENT 350.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
CRBZ WINDING OPERATING CURRENT 45.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY
CMLP THREAD QUANTITY PER INCH 40 SINGLE GROUP
CQJX NOMINAL THREAD SIZE 0.112 INCHES SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 108.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CWJS WINDING OPERATING VOLTAGE 16.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
ACZB FREQUENCY RATING 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
ABHP OVERALL LENGTH 2.250 INCHES NOMINAL
CWJS WINDING OPERATING VOLTAGE 67.70 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY

Similar Parts