NIIN Output Data
NIIN:
NSN:
Item Name:
TERMINAL , LUG
Definition:
A TERMINAL DESIGNED TO BE AFFIXED, USUALLY AT ONE END, TO A POST, STUD, CHASSIS, OR THE LIKE FOR MOUNTING. IT HAS PROVISIONS FOR ATTACHMENT OF WIRE(S) OR SIMILAR ELECTRICAL CONDUCTOR(S) IN ORDER TO ESTABLISH AN ELECTRICAL CONNECTION AND COULD REQUIRE THE USE OF TOOL(S) FOR ATTACHMENT OF WIRE. FOR POST LIKE TERMINALS, SEE TERMINAL STUD. EXCLUDES CLIP, ELECTRICAL; TERMINAL, QUICK DISCONNECT AND TERMINAL FEEDTHRU.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
NA29-2 | 09922 | A | 3 | 2 | X | XX |
CAGE Information
Code | Company |
---|---|
09922 | SOURIAU USA INC |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AGTA | BASIC SHAPE STYLE | MECHANICAL COMPRESSION |
AAMK | MOUNTING FACILITY THICKNESS | 0.312 INCHES |
AAJV | OVERALL WIDTH | 1.938 INCHES |
AALB | LARGEST WIDTH | 1.938 INCHES SINGLE END |
CSXT | DISTANCE FROM MOUNTING HOLE CENTER TO MOUNTING END | 0.578 INCHES |
AAMC | MOUNTING TONGUE WIDTH | 1.375 INCHES |
AAKV | MAXIMUM CONDUCTOR SIZE ACCOMMODATED | 250 MCM |
MATT | MATERIAL | COPPER MOUNTING FACILITY |
MATT | MATERIAL | COPPER CONDUCTOR ACCOMMODATION |
AALX | MOUNTING METHOD STYLE | STRAIGHT TWO HOLE |
CSFJ | CONDUCTOR ACCOMMODATION TYPE | DOUBLE COMPRESSION CLAMP SINGLE END |
AALV | ELECTRICAL INSULATION FEATURE | UNINSULATED |
AAJU | OVERALL LENGTH | 4.625 INCHES |
AAMA | MOUNTING HOLE DIAMETER | 0.562 INCHES |
ADHV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING HOLES ALONG LENGTH | 1.188 INCHES |