NIIN Output Data
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
591-0008-082 | 94756 | A | 5 | 2 | E | CX | ||
FLEXITE HT-105C | 03890 | A | 5 | 1 | E | CX | ||
SM-A-680085-18 | 80063 | A | 5 | 2 | A | CX | ||
PVC105-5-2-2 | 92194 | Y | C | 1 | 5 | CX | ||
ASTRA 703/105 | 91094 | F | 5 | 1 | E | CX | ||
3003 | 20999 | A | 5 | 9 | E | CX | ||
NATVAR 400/461 | 96904 | A | 3 | 1 | 4 | CX | ||
S9562-5-2 | 70210 | A | 5 | 2 | A | CX | ||
ITCO 929 | 12509 | A | 5 | 1 | 5 | CX | ||
TEMFLEX 105C | 20999 | A | 5 | 9 | E | CX | ||
3003 | 75037 | A | 5 | 9 | E | CX | ||
TEMFLEX 105C | 75037 | A | 5 | 9 | E | CX | ||
411634-1900 | 96214 | A | 5 | 2 | 5 | CX | ||
SS7114F005-0250 | 78286 | A | 5 | 2 | A | CX | ||
TURBOLEX 105 | 71124 | A | 5 | 1 | E | CX | ||
MIL-I-631 | 81349 | M | 4 | 1 | 4 | CX |
CAGE Information
Code | Company |
---|---|
03890 | MARKEL CORP. |
94756 | BOEING COMPANY, THE DIV DEFENSE, SPA |
80063 | US ARMY COMMUNICATIONS & ELECTRONICS |
92194 | ALPHA WIRE CORP |
91094 | ESSEX GROUP INC SUFLEX/IWP DIV |
20999 | 3M CO ADMININISTRATIVE ELECTRONIC & |
96904 | HIGH VOLTAGE ENGINEERING CORP NATVAR |
70210 | HONEYWELL INTERNATIONAL INC. DBA HON |
12509 | INSULTAB INC |
75037 | MINNESOTA MINING AND MFG CO 3M COMPA |
96214 | RAYTHEON COMPANY |
78286 | SIKORSKY AIRCRAFT CORPORATION |
71124 | GENERAL CABLE INDUSTRIES INC. DBA WI |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HUES | COLOR | BLACK |
AARX | INSIDE DIAMETER | 0.182 INCHES MINIMUM AND 0.198 INCHES MAXIMUM |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MOD BY COLOR |
FLEX | FLEXIBILITY | FLEXIBLE |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 700.0 VOLTS PER MIL /0.001 INCH/ |
ABJH | TEMP RATING | -10.0 DEG CELSIUS AND 105.0 DEG CELSIUS |
MATL | MATERIAL | PLASTIC,POLYVINYL CHLORIDE,MIL-I-631,TYPE F,FORM U,SUBFORM UA,GRADE C,CLASS 1,CATEGORY 1 |
AAGT | WALL THICKNESS | 0.017 INCHES MINIMUM AND 0.023 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
CQBC | MINIMUM TENSILE STRENGTH | 1800 POUNDS PER SQUARE INCH |
ZZZT | NONDEFINITIVE SPEC/STD DATA | C GRADE AND I CLASS AND 1 CATEGORY AND 5 AWG SIZE AND UA SUBFORM AND U FORM AND F TYPE |
ADZC | ENVIRONMENTAL PROTECTION | MILDEW RESISTANT AND OIL RESISTANT AND FLAME RESISTANT AND HEAT |