NIIN Output Data
NIIN:
NSN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
Reference/Part Number
CAGE Information
Code |
Company |
18876 |
U S ARMY AVIATION AND MISSILE COMMAN |
74193 |
EATON CORP HEINEMANN PRODUCTS COMMER |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.605 INCHES MAXIMUM |
BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
5.0 AMPERES AC SINGLE LOCATION |
THSD |
THREAD SERIES DESIGNATOR |
UNEF |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CQJX |
NOMINAL THREAD SIZE |
0.375 INCHES |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC SINGLE LOCATION |
PKWT |
UNPACKAGED UNIT WEIGHT |
2.100 OUNCES |
AKPX |
POLE QUANTITY |
1 |
CPRQ |
RESET METHOD |
MANUAL |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
500.0 AC SINGLE LOCATION |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE HOOK |
ABXD |
BUSHING LENGTH |
0.375 INCHES MAXIMUM |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.875 INCHES NOMINAL |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
HERMETICALLY SEALED |
ADAQ |
BODY LENGTH |
1.500 INCHES MAXIMUM |
ADTV |
CASE MATERIAL |
METAL |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
0.750 MINIMUM AT 125 PCT SINGLE LOCATION AND 3.000 MAXIMUM AT 125 PCT SINGLE LOCATION |
FREQ |
FREQUENCY IN HERTZ |
400.0 SINGLE LOCATION |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING W/PANEL SEAL |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
ADAT |
BODY WIDTH |
0.625 INCHES MAXIMUM |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
120.0 AC SINGLE LOCATION |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 SINGLE LOCATION |