NIIN Output Data
NIIN:
NSN:
Item Name:
SATURABLE REACTOR
Definition:
AN ITEM WHOSE INDUCTANCE VALUE IS CONTROLLED BY ELECTRICAL MEANS. IT DEPENDS ON THE ACTION OF THE ELECTROMAGNET FLUX PRODUCED BY THE CONTROL WINDING UPON THE EFFECTIVE PERMEABILITY OF THE CORE. IT CONTAINS TWO OR MORE WINDINGS, AT LEAST ONE OF WHICH MUST BE A CONTROL WINDING. FOR ITEMS DESIGNED TO BE USED IN CONJUNCTION WITH A RECTIFIER(S) FOR AMPLIFICATION PURPOSES, SEE AMPLIFIER, MAGNETIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
PEI 3570 | 13483 | A | 5 | 2 | 5 | ZZ | ||
1951741 | 49956 | A | 5 | 9 | 5 | TX | ||
9176113 | 18876 | A | 3 | 2 | A | TX | ||
ST29390 | 97102 | F | 5 | 9 | 5 | TX | ||
1951741 | 3B150 | A | 5 | 2 | 5 | TX | ||
8411A1-1 | 83008 | A | 5 | 9 | 5 | TX |
CAGE Information
Code | Company |
---|---|
13483 | PRECISION ELECTRONICS INC. |
49956 | RAYTHEON COMPANY DBA RAYTHEON |
18876 | U S ARMY AVIATION AND MISSILE COMMAN |
97102 | STERLING TRANSFORMER CORP |
3B150 | RAYTHEON TECHNICAL SERVICES COMPANY |
83008 | STACO ENERGY PRODUCTS CO. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CHTZ | SATURATION CURRENT RATING | 50.0 MICROAMPERES |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENT |
ADAT | BODY WIDTH | 6.000 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
TEST | TEST DATA DOCUMENT | 18876-9176113 DRAWING |
ABKW | OVERALL HEIGHT | 2.125 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRGS | DC RESISTANCE RATING IN OHMS | 138.000 SINGLE COMPONENT SINGLE CONTROL |
FEAT | SPECIAL FEATURES | ITEM HAS ONE FIXED AUTOTRANSFORMER TYPE WINDING; 240 VOLTS AC INPUT; 5.7 OHMS DC RESISTANCE ON INPUT AND OUTPUT |
ABHP | OVERALL LENGTH | 6.250 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 7 TURRET |
AXGY | MOUNTING METHOD | CLINCH NUT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 CONTROL SINGLE COMPONENT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |