NIIN Output Data
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
8034660-1334 | 18876 | A | 5 | 2 | 1 | CX | ||
267-1002P12 | 49956 | A | 5 | 9 | 3 | CX | ||
12 BLK VINYL GRADE A | 81851 | A | 3 | 2 | 5 | CX | ||
NATVAR GRADEA 12AWG BLACK B-A-1 | 96904 | A | 3 | 2 | 5 | CX | ||
MIL-I-3190 | 81349 | M | 4 | 1 | 4 | CX | ||
TURBOTUF8 12AWG BLACK B-A-1 | 71124 | A | 3 | 2 | 5 | CX | ||
VARFLO 12AWG BLACK B-A-1 | 79074 | A | 3 | 2 | 5 | CX | ||
HYGRADE VF 12AWG BLACK B-A-1 | 03890 | A | 3 | 2 | 5 | CX | ||
267-1002P12 | 3B150 | A | 3 | 2 | 3 | CX | ||
VINYL-SIL8000 12AWG BLACK B-A-1 | 81851 | A | 5 | 9 | 5 | CX | ||
TRANSFLEX 12AWG BLACK B-A-1 | 76381 | A | 5 | 9 | 5 | CX | ||
TRANSFLEX 12AWG BLACK B-A-1 | 75037 | A | 5 | 9 | 5 | CX | ||
TRANSFLEX 12AWG BLACK B-A-1 | 20999 | A | 5 | 9 | 5 | CX |
CAGE Information
Code | Company |
---|---|
03890 | MARKEL CORP. |
18876 | U S ARMY AVIATION AND MISSILE COMMAN |
49956 | RAYTHEON COMPANY DBA RAYTHEON |
81851 | FEDERAL-MOGUL CORPORATION DBA FEDERA |
96904 | HIGH VOLTAGE ENGINEERING CORP NATVAR |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
71124 | GENERAL CABLE INDUSTRIES INC. DBA WI |
79074 | VARFLEX CORPORATION DBA ELECTRICAL I |
3B150 | RAYTHEON TECHNICAL SERVICES COMPANY |
76381 | 3M COMPANY DBA 3M DIV GOVERNMENT MAR |
75037 | MINNESOTA MINING AND MFG CO 3M COMPA |
20999 | 3M CO ADMININISTRATIVE ELECTRONIC & |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGT | WALL THICKNESS | ANY ACCEPTABLE |
HUES | COLOR | BLACK |
AARX | INSIDE DIAMETER | 0.081 INCHES MINIMUM AND 0.089 INCHES MAXIMUM |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MOD BY COLOR |
ABHP | OVERALL LENGTH | 2.500 FEET MINIMUM AND 3.500 FEET MAXIMUM |
FLEX | FLEXIBILITY | FLEXIBLE |
ZZZT | NONDEFINITIVE SPEC/STD DATA | B-A-1 CLASS AND 12AWG SIZE |
ADYY | COATING MATERIAL | VINYL OR OLEORESINOUS VARNISH |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AGBE | IMPREGNATION MATERIAL | VINYL OR OLEORESINOUS VARNISH |
ABJH | TEMP RATING | 130.0 DEG CELSIUS |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
MATL | MATERIAL | GLASS BRAID, MIL-I-3190, CLASS B-A-1 |
ADZC | ENVIRONMENTAL PROTECTION | ANY ACCEPTABLE |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 7000.0 |