Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
LM11-5K0HM 77342 A 3 2 X XX

CAGE Information

Code Company
77342 TYCO ELECTRONICS CORPORATION

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
APNA WINDING DC RESISTANCE RATING 58.0 KILOHMS NOMINAL SINGLE WINDING
AKDX WINDING QUANTITY 1
ABMK OVERALL WIDTH 2.180 INCHES NOMINAL
ADZC ENVIRONMENTAL PROTECTION DUSTPROOF
THSD THREAD SERIES DESIGNATOR UNC SINGLE MOUNTING FACILITY
APCN COIL QUANTITY 1
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.812 INCHES NOMINAL SINGLE MOUNTING FACILITY
AAJD THREAD CLASS 2B SINGLE MOUNTING FACILITY
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE MOUNTING FACILITY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 5.0 AMPERES AC RESISTIVE LOAD
ABKW OVERALL HEIGHT 2.560 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC
APNP DUTY TYPE CONTINUOUS
AYSC PILE-UP MAIN CONTACT FORM ARRANGEMENT 2C
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
ABHP OVERALL LENGTH 2.250 INCHES NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE SINGLE MOUNTING FACILITY
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 28.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING

Similar Parts

LM11-5K0HM , LM115K0HM , 5945-00-899-5329 , 5945008995329 , 008995329 , LM11-5K0HM ,