NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
637-278 | 06481 | A | 3 | 2 | A | TX | ||
637-003-210 | 75138 | F | 5 | 9 | 5 | TX | ||
637-278 | 75138 | F | 5 | 9 | E | TX |
CAGE Information
Code | Company |
---|---|
06481 | NORTHROP GRUMMAN GUIDANCE AND ELECTR |
75138 | SHERJOR INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 6.2 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ABTD | MOUNTING SLOT WIDTH | 0.203 INCHES MINIMUM SINGLE GROUP AND 0.235 INCHES MAXIMUM SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
ADAQ | BODY LENGTH | 3.953 INCHES MINIMUM AND 3.985 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.688 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.782 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 240.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRMJ | WINDING POWER RATING | 150.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
ADAU | BODY HEIGHT | 4.109 INCHES MINIMUM AND 4.141 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.609 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.641 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 24.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 150.0 VOLT-AMPERE SINGLE COMPONENT |
ADAT | BODY WIDTH | 3.234 INCHES MINIMUM AND 3.266 INCHES MAXIMUM |