NIIN Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
PS1-4884-2 | 06887 | A | 5 | 9 | 5 | HD | ||
PS1-4884-2 | 23917 | A | 3 | 1 | 1 | HD |
CAGE Information
Code | Company |
---|---|
06887 | LOCKHEED MARTIN CORPORATION DBA LOCK |
23917 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRTL | CRITICALITY CODE JUSTIFICATION | ZZZY |
ABGN | BOARD OVERALL LENGTH | 13.125 INCHES |
AAMA | MOUNTING HOLE DIAMETER | 0.116 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 20 UNTHREADED HOLE |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 1.500 INCHES |
ABCZ | TERMINAL FACILITY QUANTITY PER SECTION | 0 |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY NAVORD OD42046 |
CRNL | NONFEEDTHRU TERMINAL TYPE | 434 SINGLE |
MATT | MATERIAL | GLASS FIBER BOARD AND PLASTIC EPOXY BOARD |
AAQL | BODY STYLE | STRIP TYPE |
ABGT | BOARD THICKNESS | 0.094 INCHES |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
ABDA | TERMINAL QUANTITY PER SECTION | 10 |
MATT | MATERIAL | COPPER ALLOY 360 TERMINALS |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.375 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.250 INCHES AND 2.250 INCHES AND 0.375 INCHES AND 0.375 INCHES AND 2.250 INCHES AND 0.375 INCHES AND 0.375 INCHES AND 2.250 INCHES AND 2.250 INCHES |
BWGP | SECTION QUANTITY | 5 |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.188 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES |
ABGP | BOARD OVERALL WIDTH | 2.000 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.250 INCHES |
ABCX | BOARD CONSTRUCTION | SCORED FOR EASY BREAKING INTO SMALLER TERMINAL BOARDS |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 50 SINGLE |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 35.0 |