Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
PUMP UNIT , CENTRIFUGAL

Definition:

AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED CENTRIFUGAL PUMP(S), PRIME MOVER(S), AND THE NECESSARY COMPONENTS TO PROVIDE FOR A COMPLETE OPERATION.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
LMC4 22888 A 5 1 X XX
LMC4 62272 F 3 9 5 AX
S5723 62272 F 5 9 6 HD

CAGE Information

Code Company
22888 FMC CORP
62272 CLOW CORP PUMP DIV

Federal Supply Class

Title

POWER AND HAND PUMPS

Inclusions:

Exclusions:

EXCLUDES LABORATORY JET PUMPS (FSG 65 AND 66).

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
FREQ FREQUENCY IN HERTZ 60.0
AHZF CENTRIFUGAL PUMP IMPELLER QUANTITY 1
AENK COOLING METHOD SELF VENTILATED
ADZC ENVIRONMENTAL PROTECTION DRIPPROOF
AAXS PRIME MOVER COOLING MEDIUM AIR
CBBL FEATURES PROVIDED SELF-PRIMING
AENC PUMP QUANTITY 1
ACKL MEDIA FOR WHICH DESIGNED SEWAGE
ZZZY REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS 150 GPM AT 30 FT HEAD
AKDJ PRIME MOVER TYPE ELECTRIC MOTOR
AHZG CENTRIFUGAL PUMP IMPELLER SUCTION TYPE SINGLE
AMPS CURRENT RATING IN AMPS 4.5
FAAZ PHASE THREE
AHYZ OPERATING SPEED AT RATED CAPACITY 1150.0 REVOLUTIONS PER MINUTE
AAYU INTAKE CONNECTION TYPE ROUND FLANGE
AHZA PUMPING ELEMENT OPERATING POSITION VERTICAL
AAYT INTAKE CONNECTION QUANTITY 1
AHYV MAXIMUM DISCHARGE FLOW RATE 150.0 GALLONS PER MINUTE
AAXH PRIME MOVER QUANTITY 1
AAYW DISCHARGE CONNECTION TYPE ROUND FLANGE
AAYD STAGE QUANTITY 1
AAYV DISCHARGE CONNECTION QUANTITY 1
AHYX TOTAL HEAD 30.000 FEET
AAXX MOUNTING TYPE BASE
ACDC CURRENT TYPE AC
AKNA INCLOSURE TYPE PARTIALLY INCLOSED
AHZE CENTRIFUGAL PUMP DESIGN RADIAL FLOW
ELEC VOLTAGE IN VOLTS 440.0

Similar Parts

LMC4 , LMC4 , 4320-00-914-4756 , 4320009144756 , 009144756 , LMC4 , LMC4 , S5723 ,