NIIN Output Data
NIIN:
NSN:
Item Name:
PUMP UNIT , CENTRIFUGAL
Definition:
AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED CENTRIFUGAL PUMP(S), PRIME MOVER(S), AND THE NECESSARY COMPONENTS TO PROVIDE FOR A COMPLETE OPERATION.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
850-0118 | 06991 | A | D | 9 | 5 | AX | ||
0606009 | 58181 | A | 3 | 2 | 6 | AX | ||
502912 | 04297 | A | 5 | 2 | 6 | AX |
CAGE Information
Code | Company |
---|---|
04297 | LITTLE GIANT PUMP CO |
06991 | PHILLIPS & TEMRO INDUSTRIES INC. DBA |
58181 | LMC OPERATING CORP |
Federal Supply Class
Title
POWER AND HAND PUMPS
Inclusions:
Exclusions:
EXCLUDES LABORATORY JET PUMPS (FSG 65 AND 66).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FREQ | FREQUENCY IN HERTZ | 60.0 |
AHZF | CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
ELEC | VOLTAGE IN VOLTS | 115.0 |
AAYW | DISCHARGE CONNECTION TYPE | THREADED EXTERNAL |
AHZV | SUBMERSIBILITY (NON-CORE) | NONSUBMERSIBLE |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AAYU | INTAKE CONNECTION TYPE | THREADED INTERNAL |
ASAZ | DISCHARGE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 0.250-18 NPT |
ASWT | INTAKE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 0.375-18 NPT |
AENC | PUMP QUANTITY | 1 |
AMPS | CURRENT RATING IN AMPS | 1.7 |
FEAT | SPECIAL FEATURES | FURNISHED W/2 ADAPTERS,2 HOSE CLAMPS,AND 1 MTG BRACKET |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
AHZG | CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
ADZC | ENVIRONMENTAL PROTECTION | WATERPROOF |
AHZA | PUMPING ELEMENT OPERATING POSITION | VERTICAL |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
AAXH | PRIME MOVER QUANTITY | 1 |
AAYD | STAGE QUANTITY | 1 |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
ACDC | CURRENT TYPE | AC |
AAXS | PRIME MOVER COOLING MEDIUM | OIL |
AHZE | CENTRIFUGAL PUMP DESIGN | RADIAL FLOW |
ACKL | MEDIA FOR WHICH DESIGNED | HYDROCARBON FUELS AND OILS AND WATER, FRESH |
FAAZ | PHASE | SINGLE |