NIIN Output Data
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
29881 | 97324 | A | 5 | 2 | E | KZ | ||
3430 | 92194 | Y | 3 | 2 | 4 | 75 |
CAGE Information
Code | Company |
---|---|
92194 | ALPHA WIRE CORP |
97324 | BERKSHIRE ELECTRIC CABLE CO |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 30 SINGLES |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
CXFK | VOLTAGE RATING | 1000.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR SINGLE CONDUCTOR |
MATT | MATERIAL | COPPER ALLOY 101 CORE CONDUCTOR SINGLE CONDUCTOR OR COPPER ALLOY 102 CORE CONDUCTOR SINGLE CONDUCTOR |
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 105.0 DEG CELSIUS |
AWXS | COLOR CODING DOCUMENT | 3430-92194 DRAWING |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 30 ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.650 INCHES NOMINAL |
AMQN | CONDUCTOR QUANTITY | 30 |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR |
CXDC | ROUND CONDUCTOR SIZE | 18 AWG ALL CONDUCTORS |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
HUES | COLOR | GRAY 1ST POSITION JACKET CABLE |