NIIN Output Data
Definition:
A VALVE HAVING TWO OR MORE PORTS WITH VALVE STEM OR PILOT NEEDLE IN A NORMALLY OPEN OR CLOSED POSITION. IT IS SPECIFICALLY DESIGNED TO STOP OR START OR CHANGE THE FLOW OF FLUID BY MEANS OF THE MAGNETIC ACTION OF AN ELECTRIC COIL ON A MOVEABLE CORE OR PLUNGER. THE VALVE MAY BE EQUIPPED WITH A MANUAL OPENING OR CLOSING DEVICE. FOR ITEMS WITH THREE OR MORE PORTS THAT UTILIZE A RECIPROCATING SLIDE WITH RECESS AREAS WHICH MATE WITH PORTS IN AN INTEGRAL OR REPLACEABLE PORTED SLEEVE, SEE VALVE (1), LINEAR, DIRECTIONAL CONTROL. IT MAY BE INLINE OR CARTRIDGE (MANIFOLD) DESIGN. EXCLUDES VALVE (1), BUTTERFLY.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
HA14S2 | 78462 | A | 5 | 9 | 6 | AX | ||
B14S2326 | 78462 | A | 3 | 2 | 6 | ZZ | ||
7304HS | 78462 | A | 5 | 9 | 6 | AX |
CAGE Information
Code | Company |
---|---|
78462 | SPORLAN VALVE CO |
Federal Supply Class
Title
VALVES, POWERED
Inclusions:
INCLUDES ELECTRIC MOTOR OPERATED VALVES; HYDRAULIC OPERATED VALVES; SOLENOID OPERATED VALVES.
Exclusions:
EXCLUDES ENGINE INTAKE AND EXHAUST VALVES (FSC 2990, 2815); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAAR | NOMINAL PIPE SIZE ACCOMMODATED | 0.875 INCHES ALL ENDS |
MATT | MATERIAL | STEEL CORROSION RESISTING OVERALL |
AQLR | VALVE OPERATION METHOD | SOLENOID |
BBJX | MOUNTING POSITION | HORIZONTAL OR VERTICAL |
AMPS | CURRENT RATING IN AMPS | 15.000 |
CQGM | MAXIMUM OPERATING PRESSURE | 500.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
ADQU | FLOW CONTROL DEVICE | DISK |
FREQ | FREQUENCY IN HERTZ | 50.0 AND 60.0 |
STYL | STYLE DESIGNATOR | ERR-090 |
MEDA | MEDIA FOR WHICH DESIGNED | REFRIGERANT 22 2ND RESPONSE |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 24.0 AC AND 24.0 DC AND 240.0 AC AND 240.0 DC |
AHNC | CONNECTION STYLE | SOCKET ALL ENDS |
ADSK | FLOW CONTROL DEVICE NORMAL OPERATION POSITION | OPEN |
AWLS | CONNECTION TYPE | UNTHREADED INTERNAL PIPE ALL ENDS |
MEDA | MEDIA FOR WHICH DESIGNED | REFRIGERANT 12 1ST RESPONSE |
MEDA | MEDIA FOR WHICH DESIGNED | REFRIGERANT 502 3RD RESPONSE |
FAAZ | PHASE | SINGLE |