NIIN Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
602JJY1 | 83330 | A | 5 | 9 | 4 | CX | ||
602-JJ-Y-01 | 26405 | A | 3 | 2 | 4 | CX |
CAGE Information
Code | Company |
---|---|
26405 | MARATHON SPECIAL PRODUCTS CORPORATIO |
83330 | DIALIGHT CORPORATION |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABGQ | BOARD OVERALL HEIGHT | 1.125 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.125 INCHES |
AMPS | CURRENT RATING IN AMPS | 30.0 |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 4.8 |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 1 SINGLE |
ABGN | BOARD OVERALL LENGTH | 1.531 INCHES |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.500 INCHES |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-P-19833,TYPE GDI-30F MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
CQCW | FEEDTHRU CONNECTION END TYPE | F4 15TH MATERIAL RESPONSE BOTH ENDS |
ABCS | TERMINAL ROW QUANTITY | 2 |
CRZR | FEEDTHRU TERMINAL QUANTITY | 1 SINGLE COMBINATION |
ABGP | BOARD OVERALL WIDTH | 1.312 INCHES |
CQCW | FEEDTHRU CONNECTION END TYPE | 857 FOURTH COMBINATION BOTH ENDS |
ABGS | BASE THICKNESS | 0.375 INCHES |
CWLG | TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
CSCR | TERMINAL CONNECTING LINK TYPE | 2 SINGLE |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.625 INCHES |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.562 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.500 INCHES |
MATT | MATERIAL | PLASTIC DIALLYL PHTHALATE BOARD AND GLASS FIBER BOARD |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.203 INCHES |
CWLN | TERMINAL DESIGN | FEEDTHRU |
AAMA | MOUNTING HOLE DIAMETER | 0.209 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.188 INCHES |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS AND TIN TERMINALS |
AAQL | BODY STYLE | BARRIER TYPE |