NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
SM-B-528556-2 | 80063 | A | 3 | 2 | A | TX | ||
71GB4250R27A2-5K | 98927 | F | 5 | 9 | 5 | TX | ||
2PBC-3016-2 | 02289 | H | 5 | 9 | 5 | TX | ||
SMB528556-2 | 3B150 | A | 5 | 2 | 4 | CL | ||
71GB50N-99-A-2.5K(1) | 98927 | F | 5 | 2 | 5 | TX | ||
SMB528556-2 | 49956 | A | 5 | 9 | 4 | CL |
CAGE Information
Code | Company |
---|---|
02289 | HI-G CO INC SUB OF NYTRONICS INC |
80063 | US ARMY COMMUNICATIONS & ELECTRONICS |
98927 | ELECTRONIC SPECIALTY CORP RELAY DIV |
3B150 | RAYTHEON TECHNICAL SERVICES COMPANY |
49956 | RAYTHEON COMPANY DBA RAYTHEON |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.588 INCHES MAXIMUM |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 6.0 MILLIAMPERES DC SINGLE WINDING |
APCN | COIL QUANTITY | 1 |
ABKW | OVERALL HEIGHT | 0.585 INCHES MAXIMUM |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
APNP | DUTY TYPE | CONTINUOUS |
ABMK | OVERALL WIDTH | 0.800 INCHES MAXIMUM |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 30.0 AC AND 30.0 DC |
APNA | WINDING DC RESISTANCE RATING | 2.5 KILOHMS NOMINAL SINGLE WINDING |