NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
S245A051G07 | 11660 | H | C | 1 | 6 | ZZ | AC | |
S245A051G07 | 88601 | A | 3 | 2 | X | XX | ||
24776 | 86301 | A | 5 | 2 | 5 | ZZ | ||
S245A051G07 | 79500 | A | 5 | 2 | X | XX |
CAGE Information
Code | Company |
---|---|
11660 | WESTINGHOUSE ELECTRIC CORP CONTROL B |
88601 | WESTINGHOUSE ELECTRIC CORP MEDIUM PO |
86301 | POWER PARAGON INC DBA POWER MAGNETIC |
79500 | WESTINGHOUSE ELECTRIC CORP |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BFMF | COOLING METHOD | SELF-COOLED |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 7.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 8.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CBME | CUBIC MEASURE (NON-CORE) | 977.5 CUBIC INCHES |
ADAU | BODY HEIGHT | 9.688 INCHES NOMINAL |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 3.0 KILOVOLT-AMPERE SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ADAQ | BODY LENGTH | 11.375 INCHES NOMINAL |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
AYTS | COOLING TYPE | FINS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAT | BODY WIDTH | 8.875 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.438 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |