NIIN Output Data
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OR MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
DRS12-014 | 80103 | H | 3 | 9 | 1 | TX | ||
360T | 11236 | A | 5 | 1 | 3 | TX |
CAGE Information
Code | Company |
---|---|
11236 | CTS CORP BERNE DIV THICK FILM PRODUC |
80103 | VEECO INSTRUMENTS INC LAMBDA DIV |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAQ | BODY LENGTH | 0.236 INCHES NOMINAL |
AAPN | SECTION QUANTITY | 1 |
ABMK | OVERALL WIDTH | 0.434 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AXGY | MOUNTING METHOD | TERMINAL |
ABHP | OVERALL LENGTH | 0.371 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.434 INCHES NOMINAL |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0/+20.0 SINGLE SECTION |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
ADAU | BODY HEIGHT | 0.394 INCHES NOMINAL |
AAQL | BODY STYLE | RECTANGULAR |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.300 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.135 INCHES NOMINAL |
APXH | TERMINAL LOCATION | REAR END |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 1.0 FREE AIR SINGLE SECTION |
ABKW | OVERALL HEIGHT | 0.394 INCHES NOMINAL |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 25.0 SINGLE SECTION |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 1.2 KILOHMS SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0/+100.0 SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.150 INCHES NOMINAL |