NSN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
HM2-M3-1.5-A 74193 H 5 9 E TX
AP-12-1-61-152 82227 F 5 9 E TX
AP-12-1-61-152 81541 A 3 2 E TX
SM33-1-5-240VAC6C2 74193 H E 8 E TX
HE2-A3-1.5-2 74193 H E 8 E TX
CB5503 09017 A E 8 5 TX

CAGE Information

Code Company
09017 EDO
74193 EATON CORP HEINEMANN PRODUCTS COMMER
82227 VDO CONTROL SYSTEMS INC
81541 SENSATA TECHNOLOGIES MARYLAND INC

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED SHOCK RESISTANT AND HERMETICALLY SEALED AND VIBRATION RESISTANT
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 1.5 AMPERES AC ALL LOCATIONS
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
BBRJ SPECIAL HANDLING FEATURE MAGNETIC
AEFP NONTURN DEVICE RADIUS 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.844 INCHES MINIMUM AND 0.906 INCHES MAXIMUM
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS
FREQ FREQUENCY IN HERTZ 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS
AEFQ NONTURN DEVICE LENGTH 0.063 INCHES MINIMUM AND 0.125 INCHES MAXIMUM
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
ABXD BUSHING LENGTH 0.380 INCHES MAXIMUM
AKPX POLE QUANTITY 2
THSD THREAD SERIES DESIGNATOR UNEF
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPRX ACTUATOR POSITION DESIGNATION BETWEEN POLE ONE AND TWO
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.780 INCHES MAXIMUM
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CQJX NOMINAL THREAD SIZE 0.375 INCHES
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.100 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.550 MAXIMUM AT 200 PCT ALL LOCATIONS
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS
AEFS NONTURN DEVICE DIAMETER 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM
CPRQ RESET METHOD MANUAL
TTQY TERMINAL TYPE AND QUANTITY 4 WIRE HOOK
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CPRW ACTUATOR FUNCTION TRIP-RESET
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM
ADAQ BODY LENGTH 1.500 INCHES MAXIMUM
ADTV CASE MATERIAL METAL
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
ADAT BODY WIDTH 1.250 INCHES MAXIMUM
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CMLP THREAD QUANTITY PER INCH 32
AEFN NONTURN DEVICE LOCATION AT 3 OCLOCK AND AT 9 OCLOCK