Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
7-CC 28098 A 5 9 5 TX
252-001-150-00 76374 C 5 2 5 TX
MP252-001-15AMP-125VAC 60590 A 5 9 3 TX
CC7 28098 A 3 2 5 TX
MP252-001-15AMP-125VAC 76374 C 5 9 E TX
MP252-001-15AMP-125VAC 51283 A C 1 5 ZZ 9X
252-001-150 76374 C 5 2 5 TX
13SS52AM 28098 A 5 2 5 TX

CAGE Information

Code Company
28098 MICHAEL BUSINESS MACHINES CORP
76374 EATON CORPORATION DBA FLUID POWER DI
60590 AIKEN ADVANCED SYSTEMS INC A DIV OF
51283 TECHNICAL SERVICES LABORATORY INC DB

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.880 INCHES MAXIMUM
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 5.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 30.000 MAXIMUM AT 200 PCT SINGLE LOCATION
FREQ FREQUENCY IN HERTZ 60.0 SINGLE LOCATION
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.630 INCHES NOMINAL
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 125.0 AC SINGLE LOCATION
TTQY TERMINAL TYPE AND QUANTITY 2 TAB, SOLDER LUG
AAQL BODY STYLE SINGLE POLE TYPE
AFJN FRAGILITY FACTOR MODERATELY RUGGED
ADAQ BODY LENGTH 1.440 INCHES NOMINAL
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC SINGLE LOCATION
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CQJX NOMINAL THREAD SIZE 0.375 INCHES
THSD THREAD SERIES DESIGNATOR UNS
ADTV CASE MATERIAL PLASTIC
AKPX POLE QUANTITY 1
CPRQ RESET METHOD MANUAL
CPRW ACTUATOR FUNCTION RESET
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH BUTTON
CPRJ TRIP RELEASE METHOD THERMAL SINGLE LOCATION
ADAT BODY WIDTH 0.690 INCHES NOMINAL
CMLP THREAD QUANTITY PER INCH 27
ABXD BUSHING LENGTH 0.330 INCHES NOMINAL
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED GENERAL PURPOSE
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES AC SINGLE LOCATION

Similar Parts