NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
SM-C-743392 | 80063 | A | 3 | 2 | A | TX | ||
112401 | 72149 | A | 5 | 2 | 5 | TX | ||
C743392 | 04655 | A | 5 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
04655 | GENERAL DYNAMICS C4 SYSTEMS INC. |
80063 | US ARMY COMMUNICATIONS & ELECTRONICS |
72149 | ELECTRONIC TRANSFORMER CORP. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWJS | WINDING OPERATING VOLTAGE | 37.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 22.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND 1ST GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
AXGY | MOUNTING METHOD | BRACKET 1ST GROUP AND THREADED HOLE 1ST GROUP |
CRMJ | WINDING POWER RATING | 814.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 407.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
ABHP | OVERALL LENGTH | 7.000 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES 1ST GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.250 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT ALL SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
ADAT | BODY WIDTH | 3.500 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
CWJS | WINDING OPERATING VOLTAGE | 57.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 3.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 60.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AXGY | MOUNTING METHOD | FLANGE 2ND GROUP AND SLOT 2ND GROUP |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL |
CRBZ | WINDING OPERATING CURRENT | 11.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 2ND SECONDARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.750 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 3RD SECONDARY |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 37.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
ACZB | FREQUENCY RATING | 1.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 4 ALL GROUPINGS |
THSD | THREAD SERIES DESIGNATOR | UNF 1ST GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.187 INCHES NOMINAL 2ND GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.625 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
CRMJ | WINDING POWER RATING | 126.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
AAJD | THREAD CLASS (NON-CORE) | 2B 1ST GROUP |