NIIN Output Data
Definition:
AN ITEM GENERALLY CONSISTING OF ONE OR MORE TURNS OF WIRE OR SIMILAR CONDUCTIVE MATERIAL (IN SPECIAL CASES IT MAY BE CONSIDERED AS A PARTIAL TURN). IT IS SPECIFICALLY DESIGNED TO CONCENTRATE MAGNETIC FLUX GENERATED BY THE FLOW OF AN ELECTRIC CURRENT, TO INDUCE IN ITSELF AN ELECTROMOTIVE FORCE, AND TO ADD OR SUBTRACT INDUCTIVE REACTANCE IN A CIRCUIT. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). FOR COILS WOUND ON RESISTORS WHICH ARE DESIGNED TO BE INSERTED INTO THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC..
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
SP24P | 71707 | A | E | 8 | 5 | TX | ||
9069-008 | 89536 | A | 5 | 2 | 5 | TX | ||
SP-24-P-MS | 71707 | A | 5 | 9 | 5 | TX | ||
272708 | 89536 | A | 3 | 2 | 1 | TX |
CAGE Information
Code | Company |
---|---|
71707 | COTO CORP |
89536 | FLUKE CORPORATION |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRGS | DC RESISTANCE RATING IN OHMS | 2400.000 SINGLE COMPONENT SINGLE WINDING |
ADAQ | BODY LENGTH | 1.450 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ADAR | BODY OUTSIDE DIAMETER | 0.470 INCHES NOMINAL |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
CQPZ | WINDING CONDUCTOR SIZE | 0.00249 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING |
ACZR | CORE CONSTRUCTION | POWDERED SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CWJS | WINDING OPERATING VOLTAGE | 24.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE WINDING |
ABHY | TURN QUANTITY | 15000 SINGLE COMPONENT SINGLE WINDING |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING AND WINDING TURNS SINGLE COMPONENT SINGLE WINDING |