NIIN Output Data
Definition:
AN ELECTRICAL FITTING WITH ELECTRICAL CONTACTS CONSTRUCTED TO BE AFFIXED TO THE END OF A CABLE, CONDUIT, COAXIAL LINE, CORD, WIRE (INCLUDES PRINTED/ETCHED), PRINTED WIRING BOARD, OR THE LIKE FOR CONVENIENCE IN JOINING WITH ANOTHER ELECTRICAL CONNECTOR(S) OR PRINTED WIRING BOARD. IT IS DESIGNED TO BE MOUNTED ON A BULKHEAD, CHASSIS, PANEL, WALL, PRINTED WIRING BOARD, OR THE LIKE. EXCLUDES LAMPHOLDER; JACK, TELEPHONE; JACK, TIP; INSERT ELECTRICAL CONNECTOR; INSERT MODULE, ELECTRICAL CONNECTOR; CONNECTOR BODY (AS MODIFIED) AND SOCKET, PLUG-IN ELECTRONIC COMPONENTS. SEE ALSO WIRING HARNESS (AS MODIFIED) AND CABLE ASSEMBLY (AS MODIFIED). FOR ITEMS WITH TERMINATION WIRES OF MORE THAN FOUR INCHES IN LENGTH, SEE LEAD ASSEMBLY, ELECTRICAL. FOR ITEMS WITHOUT INSERTS, SEE SHELL, ELECTRICAL CONNECTOR.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
MILC39012-38 | 81349 | M | 4 | 1 | 3 | TX | ||
M39012/38-0501 | 81349 | M | 2 | 2 | 3 | TX |
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
CONNECTORS, ELECTRICAL
Inclusions:
INCLUDES PLUGS; JACKS; RECEPTACLES, ELECTRONIC COMPONENT SOCKETS AND ASSOCIATED ACCESSORIES
Exclusions:
EXCLUDES INTERCONNECTORS, FIBER OPTIC
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.714 INCHES MINIMUM AND 0.722 INCHES MAXIMUM |
AFQX | CONTACT POSITION ARRANGEMENT STYLE | SC SINGLE MATING END |
PRMT | PRECIOUS MATERIAL | GOLD |
CXCL | INCLUDED CONTACT TYPE | COAXIAL SOCKET SINGLE MATING END SINGLE CONTACT GROUPING |
AFQW | MATING END QUANTITY | 1 |
AFRF | CONTACT MAXIMUM FREQUENCY RATING | 11000.0 MEGAHERTZ SINGLE MATING END SINGLE CONTACT GROUPING |
AAJD | THREAD CLASS | 2A AND 2B |
ADZC | ENVIRONMENTAL PROTECTION | SALT WATER RESISTANT AND SHOCK PROOF AND VIBRATION RESISTANT |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD |
AFRT | SHELL TYPE | SOLID |
AFQR | THREADED DEVICE TYPE | COUPLING FACILITY AND MOUNTING HOLE |
AAQL | BODY STYLE | STRAIGHT SHAPE W/CABLE CLAMP |
AFRD | CONTACT MAXIMUM AC VOLTAGE RATING IN VOLTS | 1000.0 SINGLE MATING END SINGLE CONTACT GROUPING |
AFRY | RADIO FREQUENCY TYPE CONTACT CHARACTERISTIC IMPEDANCE IN OHMS | 50.0 SINGLE MATING END SINGLE CONTACT GROUPING |
AAJF | THREAD DIRECTION | RIGHT-HAND AND RIGHT-HAND |
CSCF | TERMINAL TYPE | SOLDER WELL SINGLE MATING END SINGLE CONTACT GROUPING |
PMWT | PRECIOUS MATERIAL AND WEIGHT | 0.005 GOLD GRAINS, TROY |
CQTM | TERMINAL LOCATION | BACK SINGLE MATING END SINGLE CONTACT GROUPING |
ABHP | OVERALL LENGTH | 1.843 INCHES MAXIMUM |
CSPT | SHELL MATERIAL | COPPER ALLOY |
CMLP | THREAD QUANTITY PER INCH | 24 AND 32 |
ABKW | OVERALL HEIGHT | 0.995 INCHES MINIMUM AND 1.005 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.995 INCHES MINIMUM AND 1.005 INCHES MAXIMUM |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-39012/38 GOVERNMENT SPECIFICATION |
AFRW | CONNECTOR CABLE STRAIN RELIEF METHOD | COMPRESSION NUT |
ABKH | BUSHING DIAMETER | 0.690 INCHES MAXIMUM |
AFQZ | CONTACT REMOVABILITY | NONREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
THSD | THREAD SERIES DESIGNATOR | UNEF AND UNC |
CQYH | CONTACT SURFACE TREATMENT | GOLD SINGLE MATING END SINGLE CONTACT GROUPING |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-39012 SPECIFICATION |
AKMG | NOMINAL THREAD LENGTH | 0.250 INCHES AND 0.095 INCHES |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.714 INCHES MINIMUM AND 0.722 INCHES MAXIMUM |
CRBJ | CONTACT SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | MIL-G-45204,TYPE 2,CLASS 2 MIL SPEC SINGLE TREATMENT RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING |
AFQK | DISTANCE FROM MOUNTING SHOULDER TO FRONT FACE | 0.835 INCHES MINIMUM AND 0.857 INCHES MAXIMUM |
CXCG | INCLUDED CONTACT QUANTITY | 1 SINGLE MATING END SINGLE CONTACT GROUPING |
CQJX | NOMINAL THREAD SIZE | 0.687 INCHES AND 0.138 INCHES |
AFRV | CONNECTOR LOCKING METHOD | EXTERNALLY THREADED SHELL |