NIIN Output Data
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OR MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
1202P5K | 18612 | A | 3 | 1 | 3 | TX | ||
LO2344 | 16236 | A | 5 | 2 | A | ZZ |
CAGE Information
Code | Company |
---|---|
16236 | DLA LAND AND MARITIME |
18612 | VISHAY INTERTECHNOLOGY INC. |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABTB | MOUNTING HOLE DIAMETER | 0.093 INCHES NOMINAL |
AAPN | SECTION QUANTITY | 1 |
AGTP | LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS | 1.000 INCHES NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.700 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
ABWV | SHAFT DIAMETER | 0.125 INCHES NOMINAL |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AREFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 5.0 KILOHMS SINGLE SECTION |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 9000.0 NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
ADAU | BODY HEIGHT | 0.325 INCHES NOMINAL |
FEAT | SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO2344 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAT | BODY WIDTH | 0.195 INCHES NOMINAL |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
AAQL | BODY STYLE | RECTANGULAR W/MOUNTING HOLES/SLOTS |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CLUTCH |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -10.0/+10.0 SINGLE SECTION |
AKPV | MOUNTING FACILITY QUANTITY | 2 |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 9000.0 NOMINAL |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0/+5.0 SINGLE SECTION |
ADAQ | BODY LENGTH | 1.250 INCHES NOMINAL |
AXGY | MOUNTING METHOD | TERMINAL AND UNTHREADED HOLE |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
ABJT | TERMINAL LENGTH | 0.500 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.070 INCHES NOMINAL |
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE SINGLE ROW |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.900 INCHES NOMINAL |