NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
351112 | 23616 | A | 5 | 9 | 5 | TX | ||
EP4908 | 23616 | A | 5 | 2 | 5 | TX | ||
456001 | 72149 | A | 5 | 2 | 5 | TX | ||
SM-B-875042 | 80063 | A | 3 | 2 | A | TX |
CAGE Information
Code | Company |
---|---|
23616 | EPCO PRODUCTS CO |
72149 | ELECTRONIC TRANSFORMER CORP. |
80063 | US ARMY COMMUNICATIONS & ELECTRONICS |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ADAQ | BODY LENGTH | 1.620 INCHES NOMINAL |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AEHZ | MAXIMUM OPERATING TEMP | 55.0 DEG CELSIUS |
ABTB | MOUNTING HOLE DIAMETER | 0.200 INCHES NOMINAL SINGLE GROUP |
CBME | CUBIC MEASURE (NON-CORE) | 6.124 CUBIC INCHES |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 66.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 1.7 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
ADAU | BODY HEIGHT | 2.100 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.800 INCHES MAXIMUM |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
FEAT | SPECIAL FEATURES | ONE TERMINAL COMMON TO BOTH SECONDARY WINDINGS |
ABHP | OVERALL LENGTH | 2.400 INCHES MAXIMUM |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 6.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 2.9 VOLT-AMPERE SINGLE COMPONENT |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 25.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 1.2 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |