NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
PEI 9479 | 13483 | A | 5 | 2 | 5 | ZZ | ||
44B259948G01 | 03497 | A | C | 1 | 6 | ZZ | AC | |
44B259948P1 | 30221 | A | 5 | 2 | 5 | TX | ||
44B259948-001 | 30221 | A | 5 | 9 | 5 | TX | ||
44B259948G01 | 30221 | A | 5 | 9 | 5 | CX | ||
K5082 | 51181 | A | 5 | 2 | 6 | TX | ||
44B259948-001 | 01526 | H | 3 | 9 | A | TX | ||
44B259948-G01 | 01526 | H | C | 1 | 6 | ZZ | AC | |
44F242291 PIECE 20 | 01526 | H | 5 | 9 | 5 | TX |
CAGE Information
Code | Company |
---|---|
01526 | GENICOM CORP |
13483 | PRECISION ELECTRONICS INC. |
03497 | GENERAL ELECTRIC CO OUTDOOR BREAKER |
30221 | GENERAL ELECTRIC CO ARMAMENT AND ELE |
51181 | KEYTRONICS INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | NEUTRAL TAP SINGLE COMPONENT 2ND SECONDARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | BRACKET SINGLE GROUP AND SLOT SINGLE GROUP |
ADAT | BODY WIDTH | 3.500 INCHES MAXIMUM |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.250 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CBME | CUBIC MEASURE (NON-CORE) | 59.1 CUBIC INCHES |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.760 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.880 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.157 INCHES MINIMUM SINGLE GROUP AND 0.217 INCHES MAXIMUM SINGLE GROUP |
ADAU | BODY HEIGHT | 3.970 INCHES MAXIMUM |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA-WYE |
TTQY | TERMINAL TYPE AND QUANTITY | 10 TAB, SOLDER LUG |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.480 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.520 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |