NIIN Output Data
NIIN:
NSN:
Item Name:
AIR CONDITIONER
Definition:
A SELF-CONTAINED UNIT DESIGNED TO PERFORM THE FUNCTIONS OF COOLING, CIRCULATING, FILTERING, DEHUMIDIFYING OR OTHERWISE PROCESSING OF AIR. IT MAY ALSO BE EQUIPPED TO PERFORM THE ADDITIONAL FUNCTIONS OF HEATING OR HUMIDIFYING. IT MAY BE THE AIR CYCLE TYPE USED IN AIRCRAFT OR THE VAPOR CYCLE TYPE APPLICABLE TO GROUND OR AEROSPACE EQUIPMENT. EXCLUDES ENVIRONMENTAL CONTROL UNIT, PERSONNEL, SELF-CONTAINED.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
F36T4-2 | 5RQL2 | A | 3 | 2 | 5 | ZZ | ||
F36T4-2 | 94833 | A | 3 | 9 | 5 | CT |
CAGE Information
Code | Company |
---|---|
5RQL2 | DRS ENVIRONMENTAL SYSTEMS INC. |
94833 | KECO INDUSTRIES INC. |
Federal Supply Class
Title
AIR CONDITIONING EQUIPMENT
Inclusions:
INCLUDES STORE TYPE UNITS; WINDOW AND ROOM TYPE UNITS; MARINE, AND VEHICULAR AIR CONDITIONING UNITS; AIR CONDITIONING PLANTS AND SYSTEMS.
Exclusions:
EXCLUDES AIR CONDITIONING COMPONENTS (FSC 4130, OR AS OTHERWISE SPECIFICALLY PRESCRIBED BY THE INDEXES AND STRUCTURE OF THE FSC).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CYKM | HEATING CAPACITY IN BTU PER HOUR | 28000.0 NOMINAL |
AMSE | VOLTAGE RATING | 208.0 VOLTS NOMINAL |
AAXX | MOUNTING TYPE | FLOOR |
FAAZ | PHASE | THREE |
AZSF | NOMINAL COOLING CAPACITY | 1250.0 CUBIC FEET PER MINUTE |
CYJE | COOLING CAPACITY IN BTU PER HOUR | 36000.0 NOMINAL |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL |
FEAT | SPECIAL FEATURES | COOLING TOWER-NOT INCL.;EVAPORATOR CONDENDER-NOT INCL.;ACCESSORIES-NOT INCL. |
ARNA | COOLANT TYPE | FREON-22 |
AZSH | NOMINAL HEATING CAPACITY | 1250.0 CUBIC FEET PER MINUTE |
AZSD | COMPRESSOR UNIT TYPE | CLOSED |
AZAD | CONDENSER COOLING TYPE | AIR |
AWLX | ELECTRIC MOTOR QUANTITY | 3 |
ACDC | CURRENT TYPE | AC |
ALCD | USAGE DESIGN | COMPRESSOR,CONDENSER FAN,EVAPORATOR FAN |
ATJK | POWER SOURCE | ELECTRIC MOTOR |