NIIN Output Data
Definition:
TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING OR SHIELD; EACH HAVING CHARACTERISTICS NOT COMPLETELY CONFORMING TO CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY OR CORD, ELECTRICAL. INCLUDES ITEMS HAVING THE COMBINED CHARACTERISTICS OF TWO OR MORE OF THE AFOREMENTIONED NAMES. REFERS TO BULK QUANTITIES ONLY; FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
RVS0289AC20-9 | 80064 | A | C | 1 | 6 | ZZ | AC | |
M27500-20ML2U08 | 81349 | M | 5 | 9 | 4 | KZ | ||
MIL-C-27500 | 81349 | M | 5 | 9 | 4 | KZ | ||
NEMA WC27500 | 1P787 | J | 3 | 1 | E | ZZ | ||
M27500-20ML2U08 | 1P787 | J | 3 | 2 | E | ZZ | ||
M27500-20ML2U08 | D1973 | A | 5 | 9 | 2 | 9Z |
CAGE Information
Code | Company |
---|---|
1P787 | NATIONAL ELECTRICAL MFRS ASSN DBA NE |
80064 | NAVAL SHIP SYSTEMS COMMAND |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
D1973 | TYCO ELECTRONICS RAYCHEM GMBH |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AMQN | CONDUCTOR QUANTITY | 2 |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 32 ALL CONDUCTORS |
ASGF | TRACER COLOR | BLUE FIRST TRACER SECOND CONDUCTOR |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 2 SINGLES |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYALKENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
HUES | COLOR | WHITE 1ST POSITION JACKET CABLE |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXDC | ROUND CONDUCTOR SIZE | 20 AWG ALL CONDUCTORS |
HUES | COLOR | WHITE 1ST POSITION COVER ALL CONDUCTORS |
MATT | MATERIAL | COPPER ALLOY 101 CORE CONDUCTOR ALL CONDUCTORS OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD ALL MATERIAL RESPONSES CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYVINYLIDENE FLUORIDE 1ST POSITION JACKET CABLE |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
ABJH | TEMP RATING | 150.0 DEG CELSIUS |
MATT | MATERIAL | PLASTIC POLYVINYLIDENE FLUORIDE 2ND POSITION JACKET ALL CONDUCTORS |