NIIN Output Data
NIIN:
NSN:
Item Name:
MOTOR , DIRECT CURRENT
Definition:
A MOTOR WHICH IS DESIGNED FOR OPERATION FROM A DIRECT CURRENT SOURCE. EXCLUDES MOTOR, ENGINE STARTER, ELECTRICAL. SEE ALSO MOTOR, CONTROL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
48285-8-2 | 70210 | A | 3 | 2 | 4 | MF | ||
48285-4-1 | 70210 | A | 5 | 9 | 4 | MF |
CAGE Information
Code | Company |
---|---|
70210 | HONEYWELL INTERNATIONAL INC. DBA HON |
Federal Supply Class
Title
MOTORS, ELECTRICAL
Inclusions:
Exclusions:
EXCLUDES STARTING MOTORS FOR ENGINES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 26.0 LINE TO NEUTRAL SINGLE INPUT |
CWHZ | SHAFT END CHARACTERISTIC | A14 SINGLE STYLE SINGLE END |
BKPH | TORQUE RATING AND TYPE | 1.6 INCH-OUNCES STALLED |
ANPZ | INCLOSURE FEATURE | TOTALLY INCLOSED |
AKCT | SHAFT ROTATION DIRECTION | CLOCKWISE SINGLE END OR COUNTERCLOCKWISE SINGLE END |
CNXS | POWER RATING | 0.0015 HORSEPOWER OUTPUT |
AXGY | MOUNTING METHOD | PAD |
ANTN | SPECIFIC USE | ELECTRIC BUTTERFLY SHUTOFF VALVE |
BKPB | CURRENT RATING METHOD | LOAD |
BFLT | TIME INTERVAL | 1.0 MINUTES MAXIMUM ON AND 4.0 MINUTES MINIMUM OFF |
AKPS | DUTY CYCLE | INTERMITTENT |