NIIN Output Data
NIIN:
NSN:
Item Name:
FILTER , BAND PASS
Definition:
AN ITEM DESIGNED TO PASS FREQUENCIES WITHIN A SPECIFIED RANGE (BAND) AND TO SUPPRESS FREQUENCIES OUTSIDE THE RANGE (BAND). EXCLUDES A SINGLE INDUCTANCE, OR A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); REACTOR; CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
SM-A-935853 | 80063 | A | 3 | 2 | 5 | CL | ||
7500FK129 | 01456 | A | 5 | 2 | 5 | CL |
CAGE Information
Code | Company |
---|---|
01456 | MICROWAVE DEVELOPMENT LABORATORIES I |
80063 | US ARMY COMMUNICATIONS & ELECTRONICS |
Federal Supply Class
Title
FILTERS AND NETWORKS
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 500.0 MEGAHERTZ BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 CONNECTOR, RECEPTACLE INPUT-OUTPUT/GROUND |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.560 INCHES MINIMUM AND 0.564 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS BLANK |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 65.00 MEGAHERTZ BLANK AND 85.00 MEGAHERTZ BLANK |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.810 INCHES MINIMUM AND 2.814 INCHES MAXIMUM |
TEST | TEST DATA DOCUMENT | 80063-SM-A-935853 DRAWING |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
ADAU | BODY HEIGHT | 0.730 INCHES MINIMUM AND 0.770 INCHES MAXIMUM |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS BLANK |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 500.0 MEGAHERTZ BLANK |
AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.3 BLANK |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 19.0 MINIMUM BLANK AND 20.0 MAXIMUM BLANK |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 0.4 BLANK |
ADAT | BODY WIDTH | 0.580 INCHES MINIMUM AND 0.620 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 2.980 INCHES MINIMUM AND 3.020 INCHES MAXIMUM |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 65.00 MEGAHERTZ BLANK AND 85.00 MEGAHERTZ BLANK AND 16.00 MEGAHERTZ BLANK |