NIIN Output Data
NIIN:
NSN:
Item Name:
FILTER , LOW PASS
Definition:
AN ITEM DESIGNED TO PASS ALL FREQUENCIES BELOW A SPECIFIED FREQUENCY. EXCLUDES A SINGLE INDUCTANCE, A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); REACTOR; CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
T5L120-550-0 | 50140 | A | 3 | 2 | E | TX | ||
5L120-550-0 | 50140 | A | 5 | 9 | E | TX | ||
34-1235501-2 | 07397 | A | 5 | 9 | 1 | HD |
CAGE Information
Code | Company |
---|---|
07397 | GENERAL DYNAMICS ADVANCED INFORMATIO |
50140 | K&L MICROWAVE INC. |
Federal Supply Class
Title
FILTERS AND NETWORKS
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 275.0 MEGAHERTZ BLANK |
AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.5 BLANK |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +5.0/+33.0 |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 60.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK AND 3.0 MAXIMUM BLANK AND 60.0 MINIMUM BLANK |
ABHP | OVERALL LENGTH | 3.650 INCHES MINIMUM AND 3.750 INCHES MAXIMUM |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 0.75 BLANK |
ADAR | BODY OUTSIDE DIAMETER | 0.500 INCHES NOMINAL |
CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 1.0 HERTZ BLANK AND 550.0 MEGAHERTZ BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE OUTPUT |
AHCH | AVERAGE POWER RATING PER FUNCTION | 18.0 WATTS BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT |
AFGA | OPERATING TEMP RANGE | -55.0/+85.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
STYL | STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
AKNA | INCLOSURE TYPE | ENCASED |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 1.00 HERTZ BLANK AND 550.00 MEGAHERTZ BLANK |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 1.00 HERTZ BLANK AND 550.00 MEGAHERTZ BLANK AND 1.00 GIGAHERTZ BLANK AND 2.00 GIGAHERTZ BLANK |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |