NIIN Output Data
NIIN:
NSN:
Item Name:
MOTOR , ALTERNATING CURRENT
Definition:
A MOTOR WHICH IS DESIGNED FOR OPERATION FROM AN ALTERNATING CURRENT SOURCE. SEE ALSO MOTOR, CONTROL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
VAV-TF-GD | 79938 | R | 3 | 1 | 4 | 10 |
CAGE Information
Code | Company |
---|---|
79938 | EMERSON ELECTRIC CO U S ELECTRICAL M |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAJT | OVERALL HEIGHT | 21.250 INCHES |
CWCS | LENGTH OF SHAFT FROM HOUSING | 3.000 INCHES SINGLE END |
ANPZ | INCLOSURE FEATURE | TOTALLY INCLOSED |
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 230.0 LINE TO NEUTRAL LOW INPUT OR 460.0 LINE TO NEUTRAL HIGH INPUT |
CNXS | POWER RATING | 5.0000 HORSEPOWER OUTPUT |
FAAZ | PHASE | THREE INPUT |
CWFY | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 10.250 INCHES |
CWDM | SHAFT CENTER TO MOUNTING SURFACE DISTANCE | 6.250 INCHES SINGLE END |
FREQ | FREQUENCY IN HERTZ | 60.0 INPUT |
CWDT | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 10.000 INCHES |
CNMM | FRAME SIZE DESIGNATION | 15-184T-21 |
CWDY | TEMP RATING | 40.0 AMBIENT DEG CELSIUS |
AKPS | DUTY CYCLE | CONTINUOUS |
AAJU | OVERALL LENGTH | 25.500 INCHES |
AXGY | MOUNTING METHOD | FIXED BASE |
CWFX | ROTOR SPEED RATING IN RPM | 36.0 LOW FULL LOAD AND 219.0 HIGH FULL LOAD |