Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
205-11-1REC3-52F-2-303-A-M-O 81541 A 3 2 4 9Z

CAGE Information

Code Company
81541 SENSATA TECHNOLOGIES MARYLAND INC

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CQSM SWITCH LOCATION AND POSITION DESIGNATION EXTERNAL AT POLE ONE
CQQR THREAD PITCH IN MILLIMETERS 0.50
AJEC BOSS HEIGHT 0.150 INCHES NOMINAL
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 2 TOGGLE
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
AKPX POLE QUANTITY 2
THSD THREAD SERIES DESIGNATOR ISO M
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES MAXIMUM
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 10.0 AC
CPRP ULTIMATE TRIP TIME PER POLE IN SECONDS 100.000 MAXIMUM ALL LOCATIONS
CQJX NOMINAL THREAD SIZE 3.0 MILLIMETERS
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.060 INCHES NOMINAL
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.620 MINIMUM AT 200 PCT ALL LOCATIONS AND 15.000 MAXIMUM AT 200 PCT ALL LOCATIONS AND 0.030 MINIMUM AT 600 PCT ALL LOCATIONS AND 0.150 MINIMUM AT 400 PCT ALL LOCATIONS AND 1.500 MAXIMUM AT 400 PCT ALL LOCATIONS AND 0.500 MAXIMUM AT 600 PCT ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 4 THREADED STUD
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 65.0 DC ALL LOCATIONS
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.506 INCHES MAXIMUM
CBBL FEATURES PROVIDED SLIDING BAR INTERLOCK
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CTTC THREAD TOLERANCE CLASS -3 EXTERNAL
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
FEAT SPECIAL FEATURES BLACK HANDLE
ADAT BODY WIDTH 1.500 INCHES MAXIMUM
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF AND FUNGUS PROOF AND MOISTURE RESISTANT AND SALT SPRAY PROOF
CRTK SWITCH TERMINAL TYPE TAB, SOLDER LUG
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES MAXIMUM
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 DC ALL LOCATIONS
ADAQ BODY LENGTH 2.490 INCHES NOMINAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.940 INCHES NOMINAL
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE AND TWO LINKED
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30.0 AMPERES DC ALL LOCATIONS

Similar Parts

205-11-1REC3-52F-2-303-A-M-O , 205111REC352F2303AMO , 5925-01-114-4243 , 5925011144243 , 011144243 , 205-11-1REC3-52F-2-303-A-M-O ,