NIIN Output Data
NIIN:
NSN:
Item Name:
CAPACITOR , FIXED , CERAMIC DIELECTR
Definition:
A CAPACITOR, WHOSE CAPACITANCE VALUE CANNOT BE ADJUSTED OR VARIED, HAVING A CERAMIC DIELECTRIC. IT MAY BE A SINGLE UNIT, OR CONSIST OF TWO OR MORE FIXED UNITS WHICH CANNOT BE SEPARATED.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
MIL-C-39014/22 | 81349 | M | 4 | 1 | 4 | 9Z | ||
4111888-623 | 05869 | A | 5 | 2 | 5 | 9Z | ||
M39014-22-0195 | 81349 | M | 2 | 2 | 4 | 9Z | ||
R17424P2 | 16331 | A | 5 | 2 | 5 | 9Z |
CAGE Information
Code | Company |
---|---|
05869 | RAYTHEON COMPANY DBA RAYTHEON |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
16331 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 50.0 DC SINGLE SECTION |
ADAQ | BODY LENGTH | 0.260 INCHES NOMINAL |
AAQL | BODY STYLE | W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.012 INCHES NOMINAL |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
ADAU | BODY HEIGHT | 0.128 INCHES NOMINAL |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 2.5000 |
CRTP | TOLERANCE RANGE PER SECTION | -20.00/+20.00 PERCENT SINGLE SECTION |
ADAT | BODY WIDTH | 0.092 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.178 INCHES NOMINAL |
CQFB | VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE | -25.0/+15.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 1.0000 |
CQBQ | CAPACITANCE VALUE PER SECTION | 0.100 MICROFARADS SINGLE SECTION |
CWJK | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.325 INCHES NOMINAL |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-39014/22 SPECIFICATION |