NIIN Output Data
NIIN:
NSN:
Item Name:
CAPACITOR , VARIABLE , CERAMIC DIELE
Definition:
A CAPACITOR WHOSE CAPACITANCE VALUE IS CONTROLLED BY A MECHANICAL MEANS WHICH EFFECTS A CONTINUOUS VARIATION OF ITS CAPACITANCE. IT INCLUDES ITEMS CONSISTING OF TWO OR MORE VARIABLE CAPACITORS WHICH ARE INSEPARABLE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
TZ03R200FR169 | 51406 | A | 3 | 2 | E | ZZ | ||
DV2SN20D | 51406 | A | 5 | 9 | E | TX |
CAGE Information
Code | Company |
---|---|
51406 | MURATA ERIE NORTH AMERICA INC HEADQU |
Federal Supply Class
Title
CAPACITORS
Inclusions:
INCLUDES INTERFERENCE FILTER CAPACITORS; CAPACITOR MOUNTING HARDWARE.
Exclusions:
EXCLUDES SEMICONDUCTOR DEVICES AND ASSOCIATED HARDWARE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AEBC | TEMP COEFFICIENT OF CAPACITANCE IN PPM PER DEG CELSIUS | -750.0 SINGLE SECTION |
ADAQ | BODY LENGTH | 0.236 INCHES NOMINAL |
CTGN | CAPACITANCE RANGE IN PICOFARADS | +4.2/+20.0 SINGLE SECTION |
CTGP | NONDERATED VOLTAGE RATING AND TYPE | 100.0 DC CONTINUOUS SINGLE SECTION |
AFWW | TERMINAL WIDTH | 0.039 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 2 PRINTED CIRCUIT |
AEBD | TOLERANCE OF TEMP COEFFICIENT IN PPM PER DEG CELSIUS | -300.0/+300.0 SINGLE SECTION |
ADAT | BODY WIDTH | 0.236 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.197 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.189 INCHES NOMINAL |
AXGR | ADJUSTMENT DEVICE TORQUE | 0.400 INCH-OUNCES MINIMUM AND 2.800 INCH-OUNCES MAXIMUM |
CTGR | ADJUSTMENT DEVICE DRIVE TYPE AND QUANTITY | 1 SLOTTED SCREW |
ABJT | TERMINAL LENGTH | 0.128 INCHES NOMINAL |
AFWY | TERMINAL THICKNESS | 0.010 INCHES NOMINAL |
AAQL | BODY STYLE | ROTARY |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
AKNA | INCLOSURE TYPE | ENCASED |
AXGT | INSULATION DC RESISTANCE AT 25 DEG CELSIUS | 100000.0 MEGOHMS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |