NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
T235A305-1 | 78711 | A | 1 | 2 | A | TX | ||
E2827 | 05955 | A | 3 | 2 | 5 | KE | ||
T235A305-1 | 10581 | A | 5 | 2 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
05955 | EDKO ELECTRONICS |
78711 | TELEPHONICS CORPORATION DBA COMMUNIC |
10581 | STANDEX ELECTRONICS INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAU | BODY HEIGHT | 0.500 INCHES MAXIMUM |
CWJS | WINDING OPERATING VOLTAGE | 4.70 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE SECONDARY AND 5.30 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE SECONDARY |
ADAQ | BODY LENGTH | 0.557 INCHES MINIMUM AND 0.567 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAT | BODY WIDTH | 0.557 INCHES MINIMUM AND 0.567 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 1.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AGAV | END ITEM IDENTIFICATION | LAMPS MARK III |
ZZZK | SPECIFICATION/STANDARD DATA | 78711-T235A305 MANUFACTURERS SOURCE CONTROL |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 4 PIN |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |