NIIN Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
4864391 ITEM 1 | 80064 | A | 5 | 2 | A | CX | ||
605-JJ-2502-03 | 26405 | A | 3 | 2 | E | CX | ||
605-JJ-2502-3 | 83330 | A | 5 | 9 | E | CX |
CAGE Information
Code | Company |
---|---|
26405 | MARATHON SPECIAL PRODUCTS CORPORATIO |
80064 | NAVAL SHIP SYSTEMS COMMAND |
83330 | DIALIGHT CORPORATION |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.310 INCHES |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 1.125 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
AMPS | CURRENT RATING IN AMPS | 90.0 |
ABGS | BASE THICKNESS | 0.620 INCHES |
CWLN | TERMINAL DESIGN | LINKED NONFEEDTHRU |
AAMA | MOUNTING HOLE DIAMETER | 0.265 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.815 INCHES |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 2100.0 |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-P-19833,TYPE GDI-30F MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.870 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.870 INCHES |
ABGN | BOARD OVERALL LENGTH | 5.125 INCHES |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
ABGP | BOARD OVERALL WIDTH | 2.500 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 1.370 INCHES |
MATT | MATERIAL | PLASTIC DIALLYL PHTHALATE BOARD AND GLASS FIBER BOARD |
CRNL | NONFEEDTHRU TERMINAL TYPE | 599 SINGLE |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 3 SINGLE |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.500 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 1.120 INCHES |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 3 SINGLE |
AAQL | BODY STYLE | BARRIER TYPE |