NIIN Output Data
NIIN:
NSN:
Item Name:
FILTER , RADIO FREQUENCY INTERFERE
Definition:
AN ITEM DESIGNED TO SUPPRESS UNDESIRED (INTERFERING) FREQUENCIES AND HAVE A MINIMAL EFFECT ON THE DESIRED FREQUENCIES WHEN INSERTED IN AN ELECTRICAL POWER CIRCUIT. EXCLUDES ITEMS WHICH CONSIST OF A SINGLE CAPACITOR, INDUCTOR, RESISTOR, OR DEVICES CONSISTING OF ONLY TWO OR MORE CIRCUIT ELEMENTS OF THE SAME BASIC NAME. EXCLUDES FILTER, LOW PASS AND SUPPRESSOR, IGNITION INTERFERENCE. FOR ITEMS DESIGNED TO BE INSERTED IN A LINE WHICH IS PRIMARILY INTENDED TO CARRY HIGH FREQUENCY WAVES MODULATED WITH SIGNALS, SUCH AS ANTENNA LEAD-IN, SEE FILTER, BAND SUPPRESSION AND FILTER, BAND PASS. SEE ALSO LIMITER, ELECTRICAL NOISE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
EMI-F-0697 | 94117 | A | 5 | 2 | 5 | TX | ||
149023P4 | 94117 | A | 3 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
94117 | BAE SYSTEMS INFORMATION AND ELECTRON |
Federal Supply Class
Title
FILTERS AND NETWORKS
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 4TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 350.0 VOLTS AT SEA LEVEL |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 40.0 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 1ST RADIO INTERFERENCE |
ADAU | BODY HEIGHT | 2.000 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD GROUND |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 40.0 2ND RADIO INTERFERENCE |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +5.0/+55.0 |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 40.0 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 40.0 4TH RADIO INTERFERENCE |
CQRG | BODY MATERIAL | METAL |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 96906 |
ADAQ | BODY LENGTH | 10.000 INCHES NOMINAL |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 2ND RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
CRST | BODY SURFACE TREATMENT | TIN |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 THREADED STUD OUTPUT |
ADAT | BODY WIDTH | 8.000 INCHES NOMINAL |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AFGA | OPERATING TEMP RANGE | -0.0/+85.0 DEG CELSIUS |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AKNA | INCLOSURE TYPE | ENCASED |
ABHP | OVERALL LENGTH | 12.130 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 7.250 INCHES NOMINAL |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE |
AHBP | INPUT TERMINAL IDENTIFICATION | MS3102R-24-11PX |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 9.000 INCHES NOMINAL |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 3RD RADIO INTERFERENCE |
AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 4TH RADIO INTERFERENCE |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 3RD RADIO INTERFERENCE |