NIIN Output Data
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
D1754 | 04946 | A | 3 | 2 | 5 | KZ | ||
6010566-001 | 12436 | A | 7 | 2 | A | KZ |
CAGE Information
Code | Company |
---|---|
04946 | STANDARD WIRE & CABLE CO DBA AMERICA |
12436 | BAE SYSTEMS NATIONAL SECURITY SOLUTI |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B298 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | SILVER CORE CONDUCTOR ALL CONDUCTORS |
PRMT | PRECIOUS MATERIAL | SILVER |
CXFG | CONDUCTOR SEQUENCE WITHIN GROUPS | FIRST CONDUCTOR FIRST GROUP AND THIRD CONDUCTOR FIRST GROUP AND SECOND CONDUCTOR FIRST GROUP AND FOURTH CONDUCTOR FIRST GROUP |
CXFG | CONDUCTOR SEQUENCE WITHIN GROUPS | FIFTH CONDUCTOR SECOND GROUP AND SIXTH CONDUCTOR SECOND GROUP |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 2 TWISTED QUAD AND 1 TWISTED PAIR |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXDC | ROUND CONDUCTOR SIZE | 16 AWG ALL CONDUCTORS |
MATT | MATERIAL | RUBBER CHLOROPRENE CLASS CR 1ST POSITION JACKET CABLE |
PMLC | PRECIOUS MATERIAL AND LOCATION | SURFACE ALL CONDUCTORS SILVER AND SURFACE SHIELDS BRAID SILVER |
MATT | MATERIAL | PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B298 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXFG | CONDUCTOR SEQUENCE WITHIN GROUPS | SEVENTH CONDUCTOR THIRD GROUP AND EIGHTH CONDUCTOR THIRD GROUP AND NINTH CONDUCTOR THIRD GROUP AND TENTH CONDUCTOR THIRD GROUP |
FEAT | SPECIAL FEATURES | PRIMARY INSULATION CONFORMS TO L-P-403 TYPE 3 |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 29 ALL CONDUCTORS |
AMQN | CONDUCTOR QUANTITY | 10 |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.590 INCHES NOMINAL |