NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
9207-10340 | 58657 | A | 5 | 2 | 5 | TX | ||
B562 | 90536 | A | C | 1 | 5 | ZZ | AC | |
84192-009 | 16236 | A | 3 | 2 | A | TX | ||
1215448-201 | D5440 | A | 5 | 2 | 3 | YB |
CAGE Information
Code | Company |
---|---|
16236 | DLA LAND AND MARITIME |
58657 | LEACH INTERNATIONAL CORPORATION DBA |
90536 | LOCKHEED MARTIN CORPORATION DBA LOCK |
D5440 | LOCKHEED MARTIN GMBH |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ABHP | OVERALL LENGTH | 3.625 INCHES MAXIMUM |
APNA | WINDING DC RESISTANCE RATING | 44.5 OHMS NOMINAL SINGLE WINDING |
AFJN | FRAGILITY FACTOR | MODERATELY DELICATE |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW ENERGIZING ELEMENT |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC RESISTIVE LOAD AND 25.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC MOTOR LOAD AND 100.0 AMPERES DC MOTOR LOAD |
APCN | COIL QUANTITY | 1 |
TTQY | TERMINAL TYPE AND QUANTITY | 8 THREADED STUD CONTACTS |
CBME | CUBIC MEASURE | 36.071 CUBIC INCHES |
ABKW | OVERALL HEIGHT | 2.843 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC RESISTIVE LOAD AND 100.0 AMPERES DC RESISTIVE LOAD |
APNQ | ARC QUENCHING METHOD | AIR |
ABMK | OVERALL WIDTH | 3.500 INCHES MAXIMUM |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
APNP | DUTY TYPE | CONTINUOUS |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ADTV | CASE MATERIAL | METAL |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
CRXH | TIME DELAY | 0.03 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC INDUCTIVE LOAD AND 100.0 AMPERES DC INDUCTIVE LOAD |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
Similar Parts
84192-009 ,
84192009 ,
5945-01-218-7925 ,
5945012187925 ,
012187925
,
9207-10340 ,
B562 ,
84192-009 ,
1215448-201 ,