NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
2180DFE70JA-3-12-28-66 | 52090 | R | 5 | 1 | E | TX | ||
343-5547 | 52151 | A | 3 | 2 | A | TX |
CAGE Information
Code | Company |
---|---|
52090 | TELEMECANIQUE INC |
52151 | CONTINENTAL ELECTRONICS CORPORATION |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
CRXH | TIME DELAY | 0.012 SECONDS MAXIMUM FIXED RELEASE TIME |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 300.0 AC |
TTQY | TERMINAL TYPE AND QUANTITY | 16 SCREW ALL FUNCTIONS |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ABHP | OVERALL LENGTH | 2.688 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABTD | MOUNTING SLOT WIDTH | 0.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CQYJ | MOUNTING FACILITY PATTERN | DIAGONAL SINGLE MOUNTING FACILITY |
CBME | CUBIC MEASURE | 27.376 CUBIC INCHES |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 7 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
APCN | COIL QUANTITY | 1 |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AGAV | END ITEM IDENTIFICATION | OTHBANFPS118 |
CRXH | TIME DELAY | 0.022 SECONDS MAXIMUM FIXED OPERATE TIME |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 4.125 INCHES NOMINAL |
APNQ | ARC QUENCHING METHOD | AIR |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APNA | WINDING DC RESISTANCE RATING | 122.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
ABMK | OVERALL WIDTH | 2.469 INCHES NOMINAL |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC RESISTIVE LOAD |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 200.0 MILLIAMPERES DC SINGLE WINDING |