NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
550-0320-01 | 00433 | A | 3 | 9 | 5 | TX | ||
RIX550-0320-01 | 33322 | A | C | 1 | 6 | ZZ | AC |
CAGE Information
Code | Company |
---|---|
00433 | OSICOM TECHNOLOGIES INC |
33322 | GETRONICS GOVERNMENT SOLUTIONS LLC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CBBL | FEATURES PROVIDED | W/OVERLOAD PROTECTION |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CRBZ | WINDING OPERATING CURRENT | 660.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 105.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY AND 129.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN AND 4 SCREW |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAT | BODY WIDTH | 1.880 INCHES NOMINAL |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 16.0 VOLT-AMPERE SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
ACZX | WINDING SHIELDING METHOD | CORE GROUNDED AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT AND INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.200 INCHES NOMINAL |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 24.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
AXGY | MOUNTING METHOD | PLUG-IN SINGLE GROUP |
ADAU | BODY HEIGHT | 1.960 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |