NIIN Output Data
NIIN:
NSN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
Reference/Part Number
CAGE Information
Code |
Company |
81541 |
SENSATA TECHNOLOGIES MARYLAND INC |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
3.0 AMPERES AC ALL LOCATIONS |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
FREQ |
FREQUENCY IN HERTZ |
50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
AJEC |
BOSS HEIGHT |
0.150 INCHES NOMINAL |
AKPX |
POLE QUANTITY |
3 |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
10.000 NOMINAL AT 1000 PCT ALL LOCATIONS |
THSD |
THREAD SERIES DESIGNATOR |
ISO M |
CQJX |
NOMINAL THREAD SIZE |
3.0 MILLIMETERS |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
3 TOGGLE |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.060 INCHES NOMINAL |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC ALL LOCATIONS |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
ADTV |
CASE MATERIAL |
PLASTIC |
CPRQ |
RESET METHOD |
MANUAL |
ADAT |
BODY WIDTH |
1.850 INCHES NOMINAL |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SALT SPRAY PROOF AND FUNGUS RESISTANT AND MOISTURE RESISTANT AND DUSTTIGHT |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 THREADED HOLE |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
480.0 AC ALL LOCATIONS |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 ALL LOCATIONS |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 THREADED STUD |
ADAQ |
BODY LENGTH |
2.490 INCHES NOMINAL |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.940 INCHES NOMINAL |
AAQL |
BODY STYLE |
MULTIPOLE-SINGLE ACTUATOR TYPE |