Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
G165527-1 49956 A 5 9 A TX
9124-10243 58657 A 5 2 E TX
G165527-1 3B150 A 3 2 A TX

CAGE Information

Code Company
3B150 RAYTHEON TECHNICAL SERVICES COMPANY
49956 RAYTHEON COMPANY DBA RAYTHEON
58657 LEACH INTERNATIONAL CORPORATION DBA

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
CRXH TIME DELAY 0.03 SECONDS MAXIMUM FIXED OPERATE TIME
CWGM AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 5.0 AMPERES AC INDUCTIVE LOAD AND 5.0 AMPERES DC INDUCTIVE LOAD
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
ADZC ENVIRONMENTAL PROTECTION DUSTPROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 440.0 AC AND 28.0 DC
CWGM AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 1.0 AMPERES AC LAMP LOAD AND 1.0 AMPERES DC LAMP LOAD
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CSKP NONPILE-UP AUXILIARY CONTACT ARRANGEMENT 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CRXH TIME DELAY 0.05 SECONDS MAXIMUM FIXED RELEASE TIME
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.213 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.223 INCHES MAXIMUM SINGLE MOUNTING FACILITY
APCN COIL QUANTITY 1
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 15.0 AMPERES AC INDUCTIVE LOAD AND 50.0 AMPERES DC INDUCTIVE LOAD
ABKW OVERALL HEIGHT 2.297 INCHES MINIMUM AND 2.485 INCHES MAXIMUM
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
AJSS FREQUENCY IN HERTZ 60.0 NOMINAL OR 400.0 NOMINAL
APNQ ARC QUENCHING METHOD AIR
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 15.0 AMPERES AC RESISTIVE LOAD AND 50.0 AMPERES DC RESISTIVE LOAD
ABMK OVERALL WIDTH 3.150 INCHES NOMINAL
AKSL PURPOSE FOR WHICH DESIGNED GENERAL
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.240 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 3.260 INCHES MAXIMUM SINGLE MOUNTING FACILITY
TTQY TERMINAL TYPE AND QUANTITY 12 THREADED STUD ALL FUNCTIONS
APNP DUTY TYPE CONTINUOUS
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 200.0 MILLIAMPERES AC SINGLE WINDING
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 12.0 AMPERES AC MOTOR LOAD AND 50.0 AMPERES DC MOTOR LOAD
CWGM AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD
ABHP OVERALL LENGTH 3.730 INCHES MAXIMUM
CSQC AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.677 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 2.697 INCHES MAXIMUM SINGLE MOUNTING FACILITY
CQYJ MOUNTING FACILITY PATTERN RECTANGULAR SINGLE MOUNTING FACILITY

Similar Parts

G165527-1 , G1655271 , 5945-01-246-0377 , 5945012460377 , 012460377 , G165527-1 , 9124-10243 , G165527-1 ,