Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
INDICATOR , LINE VOLTAGE

Definition:

AN ITEM SPECIFICALLY DESIGNED TO TEST AND/OR MONITOR AN ELECTRICAL CIRCUIT AND INDICATE ITS OPERATING CONDITION BY MEANS OF A DISPLAY, SUCH AS LAMPS OR LIGHT EMITTING DIODES. EXAMPLES OF CONDITIONS BEING INDICATED ARE POWER ON, NO POWER, REVERSED POLARITY, OPEN GROUND, OPEN NEUTRAL, ALTERNATING CURRENT AND/OR DIRECT CURRENT. IT MAY OR MAY NOT BE USED TO INDICATE DEFINITE POWER LINE VOLTAGE RATINGS, SUCH AS 110, 220 AND 440 VOLTS. IT IS DESIGNED TO BE INSERTED IN THE CIRCUIT BEING TESTED. FOR ITEMS DESIGNED TO INDICATE WITH OUT PHYSICAL CONTACT WITH THE OBJECT BEING TESTED, SEE INDICATOR, ELECTRICAL POTENTIAL. SEE ALSO LIGHT, TEST, AND VOLTMETER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
4001416 12038 A 3 2 4 SB
M50A 12038 A 5 2 4 SB

CAGE Information

Code Company
12038 ILLINOIS TOOL WORKS INC DBA SIMCO

Federal Supply Class

Title

ELECTRICAL AND ELECTRONIC PROPER

Inclusions:

INCLUDES TEST LEADS AND TEST LEAD ATTACHMENTS; TEST INSTRUMENTS DESIGNED FOR COMMUNICATION EQUIPMENT; TEST INSTRUMENTS DESIGNED FOR USE WITH ELECTRONIC EQUIPMENT CLASSIFIED IN TWO OR MORE FSC GROUPS.

Exclusions:

EXCLUDES RADIAC EQUIPMENT

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CXCY PART NAME ASSIGNED BY CONTROLLING AGENCY WRIST STRAP MONITOR
CSBH VOLTAGE IN VOLTS AND CURRENT TYPE 120.0 AC
FEAT SPECIAL FEATURES VOLTAGE REQUIREMENTS 120 VAC, 50/60 HZ; INPUT RESISTANCE TO GROUND 3 MEGOHMS NOMINAL; RESISTANCE EXCEEDING 3 MEGOHMS TRIGGERS ALARM; OPERATING TEMP RANGE 32 DEG F TO 122 DEG F; WEIGHT 1 LB; ENCLOSURES: ALUMINUM, BEIGE AND BROWN ENAMEL INPUT JACK ON FRONT PANEL OF MONITOR; GREEN LED GLOWS TO SHOW THE WRIST STRAP IS IN PROPER WORKING ORDER; IF LED GOES OUT AND A RED LED AND AUDIBLE ALARM SOUND IT WILL ALERT THE OPERATOR TO CHECK THE STRAP; FURNISHED WITH MOUNTING BRACKET FOR MOUNTING ON OR BELOW THE WORK SURFACE; DIMENSIONS OF MONITOR 4 9/16 WIDE AND 1 15/16 INCH HIGH
FTLD FUNCTIONAL DESCRIPTION CONSTANT MONITORING OF WRIST STRAPS, DETECTS INTERMITTENT PROBLEMS, ACCEPTS ANY CONDUCTIVE WRIST STRAP WITH BANANA HZ PLUG; BUILT IN AUDIBLE AND VISUAL ALARMS; FOR USE AT STATIC PROTECTIVE WORK STATIONS; PERFORMS CONTINUITY CHECKS ON THE WRIST STRAP TO DETECT ANY OPEN CIRCUIT WHICH MAY OCCUR BETWEEN THE USER AND GROUND
ARAG CURRENT RATING 12.500 MILLIAMPERES

Similar Parts

4001416 , 4001416 , 6625-01-249-7104 , 6625012497104 , 012497104 , 4001416 , M50A ,