NIIN Output Data
NIIN:
NSN:
Item Name:
MOTOR , ALTERNATING CURRENT
Definition:
A MOTOR WHICH IS DESIGNED FOR OPERATION FROM AN ALTERNATING CURRENT SOURCE. SEE ALSO MOTOR, CONTROL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
K257 | 88422 | A | 5 | 2 | E | CX | ||
P56H1440 | 50380 | R | 5 | 9 | 5 | CX | ||
P56H1440 | 71956 | A | 3 | 2 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
50380 | RELIANCE ELECTRIC |
88422 | GENERAL ELECTRIC CO MOTOR BUSINESS G |
71956 | RELIANCE ELECTRIC COMPANY DBA RELIAN |
Federal Supply Class
Title
MOTORS, ELECTRICAL
Inclusions:
Exclusions:
EXCLUDES STARTING MOTORS FOR ENGINES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AXGY | MOUNTING METHOD | FACE |
ANPZ | INCLOSURE FEATURE | TOTALLY INCLOSED |
FAAZ | PHASE | THREE INPUT |
CNXS | POWER RATING | 1.500 HORSEPOWER OUTPUT |
FREQ | FREQUENCY IN HERTZ | 60.0 INPUT |
CWGL | CURRENT RATING IN AMPS | 5.600 FIRST MULTIPLE INPUT OR 2.800 SECOND MULTIPLE INPUT |
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 230.0 LINE TO NEUTRAL HIGH INPUT OR 208.0 LINE TO NEUTRAL LOW INPUT OR 460.0 LINE TO NEUTRAL SECOND MULTIPLE INPUT |
CWDY | TEMP RATING | 40.0 AMBIENT DEG CELSIUS |
CNMM | FRAME SIZE DESIGNATION | FC56C |
BKPQ | INCLOSURE SPECIFICATION | NEMA |
AKCT | SHAFT ROTATION DIRECTION | COUNTERCLOCKWISE SINGLE END |
AKPS | DUTY CYCLE | CONTINUOUS |
BFMF | COOLING METHOD | FAN COOLED |
BKPB | CURRENT RATING METHOD | LOAD |
CWFX | ROTOR SPEED RATING IN RPM | 1800.0 SINGLE NO LOAD |