NIIN Output Data
NIIN:
NSN:
Item Name:
OVEN , THERMAL DRYING , GAS BURNING
Definition:
AN OVEN IN WHICH HEAT IS GENERATED BY A GAS BURNING UNIT. IT MAY BE USED FOR CORE, MOLD, COIL, ARMATURE OR PAINT BAKING, THE PREHEATING OF PLEXI-GLASS OR INSTRUMENT DRYING. EXCLUDES FOOD BAKING OVENS.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
4430-4143-3455 | 99998 | A | 6 | 9 | 9 | PX | ||
VPI-52 | 0AU13 | A | 3 | 2 | 4 | MB |
CAGE Information
Code | Company |
---|---|
0AU13 | POLLUTION CONTROL PRODUCTS CO. |
99998 | DEFENSE SUPPLY CENTER RICHMOND INDUS |
Federal Supply Class
Title
INDUSTRIAL FURNACES, KILNS, LEHR
Inclusions:
INCLUDES CRUCIBLE FURNACES; CUPOLA FURNACES.
Exclusions:
EXCLUDES FOOD INDUSTRY OVENS (FSC 7310); METAL HEAT TREATING FURNACES (FSC 3424); LABORATORY TYPE FURNACES (FSC 6640).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FEAT | SPECIAL FEATURES | EXPLOSION PROOF;FLOOR IS HARD CASTABLE REFRACTORY 3IN.THK;INSULATED RATING 2300DEG F;FUELED BY NATURAL GAS,PROPANE OR NO 2 FUEL OIL;300000BTU/HR;RECLAIMING TIME 4HR |
BLST | INSULATED CABINET | PROVIDED |
ELEC | VOLTAGE IN VOLTS | 115.0 |
BLSY | ADJUSTABLE OPENING | NOT PROVIDED |
BLSX | CABINET EXHAUST VENT | PROVIDED |
BLSZ | CABINET FRESH AIR INTAKE | NOT PROVIDED |
AFEF | INSIDE DEPTH | 45.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 51.000 INCHES NOMINAL |
BJPB | CABINET DOOR QUANTITY | 1 |
BBWM | TEMP CONTROL METHOD | AUTOMATIC |
BHGT | CIRCULATION METHOD | NATURAL |
ABKW | OVERALL HEIGHT | 55.000 INCHES NOMINAL |
BLTC | THERMOMETER TYPE | ANY ACCEPTABLE |
AFMQ | INSIDE HEIGHT | 38.000 INCHES NOMINAL |
BLSR | CABINET DOUBLE WALL CONSTRUCTION | NOT PROVIDED |
ADJT | INSIDE WIDTH | 33.000 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 800.0 DEG FAHRENHEIT |
BLSQ | NORMAL OPERATING TEMP RANGE | +600.0/+850.0 DEG FAHRENHEIT |
ACDC | CURRENT TYPE | AC |
ABFY | OVERALL DEPTH | 71.000 INCHES NOMINAL |
FREQ | FREQUENCY IN HERTZ | 50.0 |
FAAZ | PHASE | SINGLE |
BLSN | WORK PROTECTION FROM HEAT SOURCE | COMPLETE |